- Date
- 09/12/2017
- W/O
- 651708
- Weather
- Dry
- Operator/Surveyor
- B.FUGATE
- Sewer ID
- Z00003
- PipeID
- P00406
- Time
- 9:59 PM
- Certificate
- U-508-7069
- System Owner
- LACSD
- Date Cleaned
- —
- Pre-Cleaning
- No Pre-Cleaning
- Media Label
- K4872
- Sewer Name
- 08 DAVIDSON CITY TRUNK, SECTS 1,2,&3
- City
- CARSON
- Loc. details
- Main Highway - Urban
- Location Code
- A
- Use of Sewer
- Sanitary Sewer
- District
- District 08
- Page No.
- 12
- Purpose
- Routine Assessment
- Project
- WO_651708_TV08001_AUG2017
- Material
- NRCP
- Shape
- Circular
- Height
- 21 in.
- Width
- 21 in.
- Upstream MH
- 08 0355
- Downstream MH
- 08 0354
- Dir. of Survey
- Downstream
- Length Surveyed
- 317.3 ft.
- Total Length
- 317.3 ft.
- Structural Index
- 3
- Structural Quick
- 3K00
- Structural Rating
- 186
- O&M Index
- 0
- O&M Quick
- 0000
- O&M Rating
- 0
- Overall Index
- 3
- Overall Quick
- —
- Overall Rating
- 186
Pipe schematic from manhole 08 0355 to 08 0354 Observation photos (2)

2.3 ft. - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

302.1 ft. - Tap Saddle, at 10 o'clock, -, within 8 inches of joint: NO, 6"