2.3 ft. - Surface Aggregate Projecting, from 07 to 05 o'clock, within 8 inches of joint: YES, Start
2.3 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 05 to 07 o'clock, , within 8 inches of joint: YES, Start
6.5 ft. - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 4"
30.2 ft. - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: YES, 4"
59.5 ft. - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 4"
86.1 ft. - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 4"
91.7 ft. - Tap Factory Made Active, at 10 o'clock, -, within 8 inches of joint: YES, 4" - MOUSE INSIDE THE CONN.
106.5 ft. - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 4" - TAP ROOTS 15%
127.3 ft. - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 4"
158.6 ft. - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 4" - 5% FINE ROOTS
178.6 ft. - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 4"
215.1 ft. - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 4"
250 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 05 to 07 o'clock, , within 8 inches of joint: YES, Finish
250 ft. - Surface Aggregate Projecting, from 07 to 05 o'clock, within 8 inches of joint: YES, Finish
| Distance | Code | Observation |
|---|---|---|
| 59.5 | TFC | — |
| 158.6 | TFC | 5% FINE ROOTS |
| 250 | SSS | — |
| 2 | SSS | — |
| 2.3 | MGO | MAG COAT START |
| 0 | MWM | — |
| 215.1 | TFC | — |
| 250 | DAGS | — |
| 6.5 | TFC | — |
| 252 | MGO | MAG COAT FINISH |
| 0 | AMH | 16 0571 |
| 127.3 | TFC | — |
| 106.5 | TFC | TAP ROOTS 15% |
| 86.1 | TFC | — |
| 252 | AMH | 16 0570 |
| 0 | MWL | — |
| 178.6 | TFC | — |
| 91.7 | TFA | MOUSE INSIDE THE CONN. |
| 2.3 | SAP | — |
| 30.2 | TF | — |
| 250 | SAP | — |
| 2.3 | DAGS | — |