Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Sep 28, 2017, 07:43 AM
Date
09/28/2017
W/O
663060
Weather
Dry
Operator/Surveyor
R.VARGAS
Sewer ID
Z00659
PipeID
P13613
Time
12:43 AM
Certificate
U-209-211
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K4279
Sewer Name
16 LAMANDA PARK TRUNK
City
PASADENA
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 16
Page No.
15
Purpose
Routine Assessment
Project
WO_630370_TV05315_AUG2017
Sewer Type
Gravity
Material
Reinforced Concrete Pipe
Shape
Circular
Height
22 in.
Width
22 in.
Upstream MH
16 0561
Downstream MH
16 0562
Dir. of Survey
Upstream
Length Surveyed
231.1 ft.
Total Length
231.1 ft.
Structural Index
3
Structural Quick
3100
Structural Rating
3
O&M Index
2
O&M Quick
2111
O&M Rating
3
Overall Index
2
Overall Quick
Overall Rating
6
Pipe schematic from manhole 16 0561 to 16 0562
MH: 16 0561MH: 16 0562upstream0 ft. AMH - Upstream Manhole, Survey Ends - 16 05625 ft. SAV - Surface Aggregate Visible, from 07 to 05 o'clock, within 8 inches of joint: YES, Finish5 ft. MGO - General Observation - MAG COAT FINISH5 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 05 to 07 o'clock, , within 8 inches of joint: YES, Finish34.3 ft. TFA - Tap Factory Made Active, at 12 o'clock, -, within 8 inches of joint: YES, 4"52.3 ft. TFA - Tap Factory Made Active, at 12 o'clock, -, within 8 inches of joint: YES, 4"76.6 ft. TFA - Tap Factory Made Active, at 12 o'clock, -, within 8 inches of joint: YES, 4"96.5 ft. TFA - Tap Factory Made Active, at 12 o'clock, -, within 8 inches of joint: YES, 4"132.7 ft. TFA - Tap Factory Made Active, at 12 o'clock, -, within 8 inches of joint: YES, 4"152 ft. TF - Tap Factory Made, at 12 o'clock, -, within 8 inches of joint: YES, 4"172.1 ft. TF - Tap Factory Made, at 12 o'clock, -, within 8 inches of joint: YES, 4"180.5 ft. TFA - Tap Factory Made Active, at 12 o'clock, -, within 8 inches of joint: YES, 4"229 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 05 to 07 o'clock, , within 8 inches of joint: YES, Start229 ft. SAV - Surface Aggregate Visible, from 07 to 05 o'clock, within 8 inches of joint: YES, Start229 ft. MGO - General Observation - MAG COAT START231.1 ft. MGO - General Observation - CONNECTION AT MH 9 O'CLOCK ACTIVE231.1 ft. MWM - Water Mark, 20 %of cross sectional area231.1 ft. VC - Vermin Cockroach231.1 ft. MGO - General Observation - CONNECTION AT MH 3 O'CLOCK ACTIVE231.1 ft. MWL - Water Level, 10 %of cross sectional area231.1 ft. AMH - Downstream Manhole, Survey Begins - 16 0561

Observation photos (2)

  • Deposits Attached Grease, 5 %of cross sectional area, from 05 to 07 o'clock,  , within 8 inches of joint: YES, Start

    2.1 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 05 to 07 o'clock, , within 8 inches of joint: YES, Start

  • Surface Aggregate Visible, from 07 to 05 o'clock, within 8 inches of joint: YES, Start

    2.1 ft. - Surface Aggregate Visible, from 07 to 05 o'clock, within 8 inches of joint: YES, Start

Observations (21)

DistanceCodeObservation
98.4TFA
0MGOCONNECTION AT MH 9 O'CLOCK ACTIVE
0MWM
226.1SAV
196.8TFA
0VC
79.1TF
59TF
231.1AMH16 0562
0MGOCONNECTION AT MH 3 O'CLOCK ACTIVE
178.8TFA
50.6TFA
0MWL
226.1MGOMAG COAT FINISH
154.5TFA
2.1DAGS
2.1SAV
226.1DAGS
0AMH16 0561
134.6TFA
2.1MGOMAG COAT START

Properties (4)

additional_info
SC352124
custom_field_two
3
customer
LACSD
datetime
2017-09-28T00:43:16-07:00