Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Sep 28, 2017, 09:47 AM
  • 08 0616_08 0615_28092017_025753.mp4

Date
09/28/2017
W/O
657842
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00008
PipeID
P00655
Time
2:47 AM
Certificate
U-508-7069
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K4890
Sewer Name
08 GRACE STREET RELIEF TRUNK
City
CARSON
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 08
Page No.
10
Purpose
Routine Assessment
Project
WO_657842_TV08018_SEP2017
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
15 in.
Width
15 in.
Upstream MH
08 0616
Downstream MH
08 0615
Dir. of Survey
Downstream
Length Surveyed
378.9 ft.
Total Length
378.9 ft.
Structural Index
2
Structural Quick
2200
Structural Rating
4
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
2
Overall Quick
Overall Rating
4
Pipe schematic from manhole 08 0616 to 08 0615
MH: 08 0616MH: 08 0615downstream0 ft. MWM - Water Mark, 25 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 08 06160 ft. MWL - Water Level, 10 %of cross sectional area153.9 ft. CL - Crack Longitudinal, at 02 o'clock, within 8 inches of joint: YES369.4 ft. CL - Crack Longitudinal, at 02 o'clock, within 8 inches of joint: YES377 ft. MGO - General Observation - SPALLING THROUGHOUT THE REACH378.9 ft. AMH - Downstream Manhole, Survey Ends - 08 0615

Observation photos (2)

  • Crack Longitudinal, at 02 o'clock, within 8 inches of joint: YES

    153.9 ft. - Crack Longitudinal, at 02 o'clock, within 8 inches of joint: YES

  • Crack Longitudinal, at 02 o'clock, within 8 inches of joint: YES

    369.4 ft. - Crack Longitudinal, at 02 o'clock, within 8 inches of joint: YES

Observations (7)

DistanceCodeObservation
369.4CL
378.9AMH08 0615
0MWM
153.9CL
0AMH08 0616
377MGOSPALLING THROUGHOUT THE REACH
0MWL