- Date
- 09/20/2017
- W/O
- 657830
- Weather
- Dry
- Operator/Surveyor
- S. LOPEZ
- Sewer ID
- Z00584
- PipeID
- P18232
- Time
- 1:03 AM
- Certificate
- U-111-11880
- System Owner
- LACSD
- Date Cleaned
- —
- Pre-Cleaning
- No Pre-Cleaning
- Media Label
- K4729
- Sewer Name
- 14 WEST SIDE TRUNK
- City
- LANCASTER
- Loc. details
- Main Highway - Suburban/Rural
- Location Code
- B
- Use of Sewer
- Sanitary Sewer
- District
- District 14
- Page No.
- 18
- Purpose
- Routine Assessment
- Project
- WO_657830_TV14033_SEP2017
- Material
- Vitrified Clay Pipe
- Shape
- Circular
- Height
- 8 in.
- Width
- 8 in.
- Upstream MH
- 14 0193
- Downstream MH
- 14 0192
- Dir. of Survey
- Downstream
- Length Surveyed
- 326.1 ft.
- Total Length
- 326.1 ft.
- Structural Index
- 3
- Structural Quick
- 3J00
- Structural Rating
- 168
- O&M Index
- 2
- O&M Quick
- 2L00
- O&M Rating
- 130
- Overall Index
- 2
- Overall Quick
- —
- Overall Rating
- 298
Pipe schematic from manhole 14 0193 to 14 0192 Observation photos (3)

2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Start

25.3 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

49 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start