Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0May 18, 2017, 08:51 AM
  • 18 0865_18 0864_20170518_020641.mp4

Date
05/18/2017
W/O
635479
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00709
PipeID
P14717
Time
1:51 AM
Certificate
U-508-7069
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K4499
Sewer Name
18 SO WHITTIER OUTFALL RLF TR, SECTS 1,2A,2B,2C,&3
City
SANTA FE SPRINGS
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 18
Page No.
34
Purpose
Routine Assessment
Project
WO_635479_TV18051_MAY2017
Material
Reinforced Concrete Pipe
Shape
Circular
Height
48 in.
Width
48 in.
Upstream MH
18 0865
Downstream MH
18 0864
Dir. of Survey
Downstream
Length Surveyed
512.5 ft.
Total Length
512.5 ft.
Structural Index
3
Structural Quick
3K00
Structural Rating
186
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
186
Pipe schematic from manhole 18 0865 to 18 0864
MH: 18 0865MH: 18 0864downstream0 ft. MWM - Water Mark, 25 %of cross sectional area0 ft. MWL - Water Level, 15 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 18 08652.1 ft. MGO - General Observation - MAG COAT134.8 ft. SAP - Surface Aggregate Projecting, from 07 to 09 o'clock, within 8 inches of joint: NO138.2 ft. SAP - Surface Aggregate Projecting, from 07 to 09 o'clock, within 8 inches of joint: NO, Finish203.8 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start509.3 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish512.5 ft. MGO - General Observation - CONNECTION AT MH 3 O'CLOCK512.5 ft. AMH - Downstream Manhole, Survey Ends - 18 0864

Observation photos (2)

  • Surface Aggregate Projecting, from 07 to 09 o'clock, within 8 inches of joint: NO

    134.8 ft. - Surface Aggregate Projecting, from 07 to 09 o'clock, within 8 inches of joint: NO

  • Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    203.8 ft. - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

Observations (10)

DistanceCodeObservation
0MWM
512.5MGOCONNECTION AT MH 3 O'CLOCK
509.3SAV
512.5AMH18 0864
2.1MGOMAG COAT
0MWL
203.8SAV
134.8SAP
0AMH18 0865
138.2SAP

Properties (5)

additional_info
SC345308
custom_field_two
3
customer
LACSD
datetime
2017-05-18T01:51:11-07:00
sewer_category
Gravity