Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Mar 11, 2016, 07:58 AM
  • 19 0082_19 0081_20160311_012215.mp4

Date
03/10/2016
W/O
557968
Weather
Dry
Operator/Surveyor
J. HARTOOG
Sewer ID
Z00722
PipeID
P15274
Time
11:58 PM
Certificate
U-507-03-3386
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K3222
Sewer Name
19 EAST ARTESIA TRUNK, SECTS 1,2,3,&5
City
LAKEWOOD, CA
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 19
Page No.
06
Purpose
Routine Assessment
Project
WO_557968_TV19021_2016MAR
Material
Vitrified Clay Pipe
Shape
Circular
Height
21 in.
Upstream MH
19 0082
Downstream MH
19 0081
Dir. of Survey
Downstream
Length Surveyed
512.1 ft.
Total Length
512.1 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
2
O&M Quick
2T11
O&M Rating
215
Overall Index
2
Overall Quick
Overall Rating
215
Pipe schematic from manhole 19 0082 to 19 0081
MH: 19 0082MH: 19 0081downstream0 ft. MWM - Water Mark, 30 %of cross sectional area0 ft. MWL - Water Level, 20 %of cross sectional area0 ft. MGO - General Observation - CAPPED LATERAL 9 O'CLOCK @ MH0 ft. AMH - Upstream Manhole, Survey Begins - 19 00824.3 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start60 ft. TBC - Tap Break-In Capped, at 02 o'clock, -, within 8 inches of joint: NO, 4"109.2 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 4"164.2 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: YES, 4"225.3 ft. TBC - Tap Break-In Capped, at 02 o'clock, -, within 8 inches of joint: YES, 4"268.9 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 4"317 ft. TBC - Tap Break-In Capped, at 02 o'clock, -, within 8 inches of joint: NO, 4"371.1 ft. TBC - Tap Break-In Capped, at 02 o'clock, -, within 8 inches of joint: NO, 4"410.7 ft. TBC - Tap Break-In Capped, at 02 o'clock, -, within 8 inches of joint: YES, 4"459.4 ft. TBC - Tap Break-In Capped, at 02 o'clock, -, within 8 inches of joint: NO, 4"509 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish512.1 ft. AMH - Downstream Manhole, Survey Ends - 19 0081512.1 ft. VC - Vermin Cockroach

Observations (17)

DistanceCodeObservation
225.3TBC
509DAGS
60TBC
512.1AMH19 0081
109.2TFC
4.3DAGS
0MWM
459.4TBC
0MWL
317TBC
0MGOCAPPED LATERAL 9 O'CLOCK @ MH
268.9TFC
371.1TBC
0AMH19 0082
410.7TBC
164.2TFC
512.1VC

Properties (5)

additional_info
SC305312
custom_field_two
4
customer
LACSD
datetime
2016-03-10T23:58:21-08:00
sewer_category