Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Nov 18, 2016, 09:59 AM
  • 16 0508_16 0507 _20161118_020157.mp4

Date
11/18/2016
W/O
596918
Weather
Dry
Operator/Surveyor
R.VARGAS
Sewer ID
Z00659
PipeID
P13559
Time
1:59 AM
Certificate
U-209-211
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K3882
Sewer Name
16 LAMANDA PARK TRUNK
City
SAN MARINO
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 16
Page No.
18
Purpose
Routine Assessment
Project
WO_596918_TV16026_NOV2016
Material
Vitrified Clay Pipe
Shape
Circular
Height
30 in.
Width
30 in.
Upstream MH
16 0508
Downstream MH
16 0507
Dir. of Survey
Downstream
Length Surveyed
292.9 ft.
Total Length
292.9 ft.
Structural Index
2
Structural Quick
2100
Structural Rating
2
O&M Index
3
O&M Quick
4231
O&M Rating
14
Overall Index
3
Overall Quick
Overall Rating
16
Pipe schematic from manhole 16 0508 to 16 0507
MH: 16 0508MH: 16 0507downstream0 ft. MWM - Water Mark, 20 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 16 05080 ft. MWL - Water Level, 15 %of cross sectional area0 ft. MGO - General Observation - LATERAL AT MH 3 O CLOCK ACTIVE4.6 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start24.4 ft. VC - Vermin Cockroach83.4 ft. TBA - Tap Break-In Active, at 01 o'clock, -, within 8 inches of joint: YES, 6"142.1 ft. TBA - Tap Break-In Active, at 01 o'clock, -, within 8 inches of joint: YES, 6"203.3 ft. CL - Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES206.6 ft. TBA - Tap Break-In Active, at 01 o'clock, -, within 8 inches of joint: YES, 6"219.3 ft. TBA - Tap Break-In Active, at 11 o'clock, -, within 8 inches of joint: YES, 6"270.8 ft. TBA - Tap Break-In Active, at 01 o'clock, -, within 8 inches of joint: YES, 6"280.3 ft. TBA - Tap Break-In Active, at 11 o'clock, -, within 8 inches of joint: YES, 6"281.4 ft. TBA - Tap Break-In Active, at 01 o'clock, -, within 8 inches of joint: YES, 6"287.6 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish292.9 ft. AMH - Downstream Manhole, Survey Ends - 16 0507

Observation photos (8)

  • Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock,  , within 8 inches of joint: YES, Start

    4.6 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start

  • Tap Break-In Active, at 01 o'clock, -, within 8 inches of joint: YES, 6"

    83.4 ft. - Tap Break-In Active, at 01 o'clock, -, within 8 inches of joint: YES, 6"

  • Tap Break-In Active, at 01 o'clock, -, within 8 inches of joint: YES, 6"

    142.1 ft. - Tap Break-In Active, at 01 o'clock, -, within 8 inches of joint: YES, 6"

  • Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES

    203.3 ft. - Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES

  • Tap Break-In Active, at 01 o'clock, -, within 8 inches of joint: YES, 6"

    206.6 ft. - Tap Break-In Active, at 01 o'clock, -, within 8 inches of joint: YES, 6"

  • Tap Break-In Active, at 11 o'clock, -, within 8 inches of joint: YES, 6"

    219.3 ft. - Tap Break-In Active, at 11 o'clock, -, within 8 inches of joint: YES, 6"

  • Tap Break-In Active, at 01 o'clock, -, within 8 inches of joint: YES, 6"

    270.8 ft. - Tap Break-In Active, at 01 o'clock, -, within 8 inches of joint: YES, 6"

  • Tap Break-In Active, at 01 o'clock, -, within 8 inches of joint: YES, 6"

    281.4 ft. - Tap Break-In Active, at 01 o'clock, -, within 8 inches of joint: YES, 6"

Observations (16)

DistanceCodeObservation
24.4VC
0MWM
287.6DAGS
0AMH16 0508
281.4TBA
83.4TBA
0MWL
280.3TBA
270.8TBA
206.6TBA
219.3TBA
203.3CL
4.6DAGS
142.1TBA
292.9AMH16 0507
0MGOLATERAL AT MH 3 O CLOCK ACTIVE

Properties (5)

additional_info
SC305215
custom_field_two
4
customer
LACSD
datetime
2016-11-18T01:59:28-08:00
sewer_category
Gravity