16 0521_16 0520 _11172016_001938.mp4
4.5 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start
4.8 ft. - Roots Medium Joint, from 08 to 04 o'clock, 20 %, within 8 inches of joint: YESR, Start
21.8 ft. - Tap Break-In Active, at 11 o'clock, -, within 8 inches of joint: YES, 6"
28.1 ft. - Tap Break-In Active, at 02 o'clock, -, within 8 inches of joint: YES, 6"
70.8 ft. - Tap Break-In Intruding, at 03 o'clock, -, -, within 8 inches of joint: YES, 6", 1"
81.7 ft. - Fracture Multiple, from 10 to 02 o'clock, within 8 inches of joint: YES, Start
98.1 ft. - Roots Medium Lateral, at 12 o'clock, 10 %, within 8 inches of joint: YES
98.1 ft. - Tap Break-In Active, at 12 o'clock, -, within 8 inches of joint: YES, 6"
154.4 ft. - Tap Break-In Active, at 12 o'clock, -, within 8 inches of joint: YES, 6"
167.9 ft. - Tap Break-In Active, at 12 o'clock, -, within 8 inches of joint: YES, 6"
| Distance | Code | Observation |
|---|---|---|
| 28.1 | TBA | — |
| 167.9 | TBA | — |
| 181.9 | MGO | LATERAL AT MH 3 O CLOCK CAPPED |
| 81.7 | FM | — |
| 98.1 | RML | — |
| 177 | DAGS | — |
| 4.5 | DAGS | — |
| 32.4 | RMJ | — |
| 70.8 | TBI | — |
| 21.8 | TBA | — |
| 0 | MWM | — |
| 173.9 | FM | — |
| 0 | AMH | 16 0521 |
| 0 | MWL | — |
| 98.1 | TBA | — |
| 4.8 | RMJ | — |
| 154.4 | TBA | — |
| 181.9 | AMH | 16 0520 |