16 0510_16 0509 _11172016_040924.mp4
2.4 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start
8 ft. - Tap Break-In, at 11 o'clock, -, within 8 inches of joint: YES, 6"
8.1 ft. - Tap Break-In Active, at 01 o'clock, -, within 8 inches of joint: YES, 6"
77 ft. - Tap Break-In Active, at 01 o'clock, -, within 8 inches of joint: YES, 6"
126.2 ft. - Tap Break-In Active, at 11 o'clock, -, within 8 inches of joint: YES, 6"
139.4 ft. - Tap Break-In Active, at 01 o'clock, -, within 8 inches of joint: YES, 6"
182.4 ft. - Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES
182.9 ft. - Tap Break-In Active, at 11 o'clock, -, within 8 inches of joint: YES, 6"
206.1 ft. - Tap Break-In Active, at 01 o'clock, -, within 8 inches of joint: YES, 6"
241.8 ft. - Tap Break-In Active, at 11 o'clock, -, within 8 inches of joint: YES, 6"
| Distance | Code | Observation |
|---|---|---|
| 139.4 | TBA | — |
| 241.8 | TBA | — |
| 77 | TBA | — |
| 263 | AMH | 16 0509 |
| 0 | MWM | — |
| 126.2 | TBA | — |
| 182.9 | TBA | — |
| 0 | AMH | 16 0510 |
| 2.4 | DAGS | — |
| 182.4 | CL | — |
| 8.1 | TBA | — |
| 260.5 | DAGS | — |
| 0 | MWL | — |
| 206.1 | TBA | — |
| 8 | TB | — |
| 64.5 | TBA | — |