16 0504_16 0503 _20161118_033020.mp4
2.3 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start
16.9 ft. - Tap Break-In Active, at 11 o'clock, -, within 8 inches of joint: YES, 6"
62.9 ft. - Tap Break-In Active, at 11 o'clock, -, within 8 inches of joint: YES, 6"
112.3 ft. - Tap Break-In Active, at 01 o'clock, -, within 8 inches of joint: YES, 6"
120.6 ft. - Tap Break-In Active, at 11 o'clock, -, within 8 inches of joint: YES, 6"
121.2 ft. - Crack Circumferential, from 10 to 11 o'clock, within 8 inches of joint: YES
143 ft. - Tap Break-In Active, at 11 o'clock, -, within 8 inches of joint: YES, 6"
170.5 ft. - Tap Break-In Active, at 12 o'clock, -, within 8 inches of joint: YES, 6"
183 ft. - Tap Break-In Active, at 01 o'clock, -, within 8 inches of joint: YES, 6"
200.2 ft. - Tap Break-In Active, at 11 o'clock, -, within 8 inches of joint: YES, 6"
271 ft. - Roots Medium Connection, from 09 to 01 o'clock, 30 %, within 8 inches of joint: YES
271 ft. - Tap Break-In Active, at 11 o'clock, -, within 8 inches of joint: YES, 6"
276 ft. - Tap Break-In Active, at 01 o'clock, -, within 8 inches of joint: YES, 6"
305.7 ft. - Tap Break-In Active, at 12 o'clock, -, within 8 inches of joint: YES, 6"
| Distance | Code | Observation |
|---|---|---|
| 170.5 | TBA | — |
| 62.9 | TBA | — |
| 276 | RFL | — |
| 271 | RMC | — |
| 308.5 | DAGS | — |
| 271 | TBA | — |
| 16.9 | TBA | — |
| 200.2 | TBA | — |
| 121.2 | CC | — |
| 0 | MWL | — |
| 2.3 | DAGS | — |
| 0 | AMH | 16 0504 |
| 305.7 | TBA | — |
| 276 | TBA | — |
| 143 | TBA | — |
| 309.4 | AMH | 16 0503 |
| 305 | RMC | — |
| 183 | TBA | — |
| 112.3 | TBA | — |
| 0 | MWM | — |
| 120.6 | TBA | — |
| 0 | VC | — |
| 0 | MGO | LATERAL AT MH 3 O CLOCK ACTIVE |