16 0520_16 0519 _11172016_003910.mp4
3.6 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start
21.3 ft. - Tap Break-In Active, at 10 o'clock, -, within 8 inches of joint: YES, 6"
58.6 ft. - Tap Break-In Active, at 12 o'clock, -, within 8 inches of joint: YES, 6"
75.8 ft. - Tap Break-In Active, at 01 o'clock, -, within 8 inches of joint: YES, 6", 6"
101.7 ft. - Tap Break-In Active, at 02 o'clock, -, within 8 inches of joint: YES, 6"
154.5 ft. - Tap Break-In Active, at 12 o'clock, -, within 8 inches of joint: YES, 6"
185 ft. - Tap Break-In Active, at 12 o'clock, -, within 8 inches of joint: YES, 6"
217.9 ft. - Tap Break-In Active, at 02 o'clock, -, within 8 inches of joint: YES, 6"
234.1 ft. - Crack Circumferential, from 11 to 01 o'clock, within 8 inches of joint: YES
| Distance | Code | Observation |
|---|---|---|
| 246.6 | MGO | LATERAL AT MH 9 O CLOCK ACTIVE |
| 0 | MGO | LATERAL AT MH 3 O CLOCK CAPPED |
| 58.6 | RFC | — |
| 58.6 | TBA | — |
| 3.6 | DAGS | — |
| 21.3 | TBA | — |
| 0 | AMH | 16 0520 |
| 217.9 | TBA | — |
| 75.8 | TBA | — |
| 234.1 | CC | — |
| 0 | MWL | — |
| 185 | TBA | — |
| 243 | DAGS | — |
| 246.6 | AMH | 16 0519 |
| 0 | MWM | — |
| 101.7 | TBA | — |
| 154.5 | TBA | — |