- Date
- 04/27/2016
- W/O
- 557418
- Weather
- Dry
- Operator/Surveyor
- N.ZAHREDDINE
- Sewer ID
- Z00784
- PipeID
- P16103
- Time
- 12:01 AM
- Certificate
- U-109-7948
- System Owner
- LACSD
- Date Cleaned
- —
- Pre-Cleaning
- Not Known
- Media Label
- K 3192
- Sewer Name
- 21 SAN ANTONIO TRUNK
- City
- POMONA
- Loc. details
- Light Highway
- Location Code
- C
- Use of Sewer
- Sanitary Sewer
- District
- District 21
- Page No.
- 06
- Purpose
- Routine Assessment
- Project
- WO_557418_TV21023_APRIL2016
- Material
- Vitrified Clay Pipe
- Shape
- Circular
- Height
- 15 in.
- Upstream MH
- 21 1003
- Downstream MH
- 21 1002
- Dir. of Survey
- Downstream
- Length Surveyed
- 302.4 ft.
- Total Length
- 302.4 ft.
- Structural Index
- 4
- Structural Quick
- 4400
- Structural Rating
- 16
- O&M Index
- 1
- O&M Quick
- 1200
- O&M Rating
- 2
- Overall Index
- 3
- Overall Quick
- —
- Overall Rating
- 18
Pipe schematic from manhole 21 1003 to 21 1002 Observation photos (4)

74.8 ft. - Fracture Multiple, from 07 to 11 o'clock, within 8 inches of joint: YES

78.5 ft. - Fracture Multiple, from 11 to 05 o'clock, within 8 inches of joint: YES

101.4 ft. - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

129.1 ft. - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start