Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Apr 26, 2016, 09:15 AM
  • 21 1009_21 1008_20160426_034052.mp4

Date
04/26/2016
W/O
557418
Weather
Dry
Operator/Surveyor
N.ZAHREDDINE
Sewer ID
Z00784
PipeID
P16109
Time
2:15 AM
Certificate
U-109-7948
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K 3191
Sewer Name
21 SAN ANTONIO TRUNK
City
POMONA
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 21
Page No.
06
Purpose
Routine Assessment
Project
WO_557418_TV21023_APRIL2016
Material
Vitrified Clay Pipe
Shape
Circular
Height
12 in.
Upstream MH
21 1009
Downstream MH
21 1008
Dir. of Survey
Downstream
Length Surveyed
267.5 ft.
Total Length
267.5 ft.
Structural Index
4
Structural Quick
5142
Structural Rating
19
O&M Index
1
O&M Quick
1200
O&M Rating
2
Overall Index
3
Overall Quick
Overall Rating
21
Pipe schematic from manhole 21 1009 to 21 1008
MH: 21 1009MH: 21 1008downstream0 ft. MWL - Water Level, 5 %of cross sectional area0 ft. MWM - Water Mark, 25 %of cross sectional area0 ft. MGO - General Observation - CONNECTION AT THE MH 3 OC'LOCK0 ft. AMH - Upstream Manhole, Survey Begins - 21 10090 ft. VC - Vermin Cockroach4.7 ft. FM - Fracture Multiple, from 02 to 04 o'clock, within 8 inches of joint: YES9.8 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 4"11.5 ft. CM - Crack Multiple, from 10 to 04 o'clock, within 8 inches of joint: YES23.7 ft. FM - Fracture Multiple, from 07 to 01 o'clock, within 8 inches of joint: YES26.9 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start42.1 ft. B - Broken, from 01 to 04 o'clock, within 8 inches of joint: YES49.3 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 4"70.5 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 4", 4"97.7 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 4"143.8 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 4"149.2 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 4"192.4 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 4"197.9 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 4"246.5 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 4"249.2 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 4"265.9 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish267.5 ft. AMH - Downstream Manhole, Survey Ends - 21 1008267.5 ft. VC - Vermin Cockroach

Observation photos (5)

  • Fracture Multiple, from 02 to 04 o'clock, within 8 inches of joint: YES

    4.7 ft. - Fracture Multiple, from 02 to 04 o'clock, within 8 inches of joint: YES

  • Crack Multiple, from 10 to 04 o'clock, within 8 inches of joint: YES

    11.5 ft. - Crack Multiple, from 10 to 04 o'clock, within 8 inches of joint: YES

  • Fracture Multiple, from 07 to 01 o'clock, within 8 inches of joint: YES

    23.7 ft. - Fracture Multiple, from 07 to 01 o'clock, within 8 inches of joint: YES

  • Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    26.9 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Broken, from 01 to 04 o'clock, within 8 inches of joint: YES

    42.1 ft. - Broken, from 01 to 04 o'clock, within 8 inches of joint: YES

Observations (23)

DistanceCodeObservation
267.5AMH21 1008
0MWL
267.5VC
42.1B
97.7TFC
249.2TFC
4.7FM
0MWM
11.5CM
265.9CM
0MGOCONNECTION AT THE MH 3 OC'LOCK
0AMH21 1009
143.8TF
192.4TFC
0VC
9.8TF
246.5TFC
49.3TFC
197.9TFC
70.5TF
23.7FM
149.2TFC
26.9CM

Properties (5)

additional_info
SC226239
custom_field_two
2
customer
LACSD
datetime
2016-04-26T02:15:56-07:00
sewer_category