Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Apr 26, 2016, 06:08 AM
  • 21 1016_21 1015_20160426_002732.mp4

Date
04/25/2016
W/O
557418
Weather
Dry
Operator/Surveyor
N.ZAHREDDINE
Sewer ID
Z00784
PipeID
P16116
Time
11:08 PM
Certificate
U-109-7948
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K3191
Sewer Name
21 SAN ANTONIO TRUNK
City
POMONA
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 21
Page No.
06
Purpose
Routine Assessment
Project
WO_557418_TV21023_APRIL2016
Material
Vitrified Clay Pipe
Shape
Circular
Height
15 in.
Upstream MH
21 1016
Downstream MH
21 1015
Dir. of Survey
Downstream
Length Surveyed
314.2 ft.
Total Length
314.2 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
1
O&M Quick
1200
O&M Rating
2
Overall Index
1
Overall Quick
Overall Rating
2
Pipe schematic from manhole 21 1016 to 21 1015
MH: 21 1016MH: 21 1015downstream0 ft. VC - Vermin Cockroach0 ft. MWM - Water Mark, 30 %of cross sectional area0 ft. MGO - General Observation - CONNECTION AT THE MH 3 OC'LOCK0 ft. MGO - General Observation - CONNECTION AT THE MH 9 OC'LOCK0 ft. AMH - Upstream Manhole, Survey Begins - 21 10160 ft. MWL - Water Level, 5 %of cross sectional area10.7 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 4"15.8 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 4"56.7 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 4"61.7 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 4"106.7 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 4"111.3 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 4"156.9 ft. TFC - Tap Factory Made Capped, at 11 o'clock, -, within 8 inches of joint: NO, 4"161.8 ft. TFC - Tap Factory Made Capped, at 01 o'clock, -, within 8 inches of joint: NO, 4"167.6 ft. TBA - Tap Break-In Active, at 12 o'clock, -, within 8 inches of joint: NO, 6"208.3 ft. TFC - Tap Factory Made Capped, at 11 o'clock, -, within 8 inches of joint: NO, 4"211.9 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 4"258 ft. TB - Tap Break-In, at 10 o'clock, -, within 8 inches of joint: NO, 4"263.2 ft. TFC - Tap Factory Made Capped, at 01 o'clock, -, within 8 inches of joint: NO, 4"303.5 ft. TFC - Tap Factory Made Capped, at 11 o'clock, -, within 8 inches of joint: NO, 4"308.5 ft. TFC - Tap Factory Made Capped, at 01 o'clock, -, within 8 inches of joint: NO, 4"314.2 ft. VC - Vermin Cockroach314.2 ft. MGO - General Observation - CONNECTION AT THE MH 3 OC'LOCK314.2 ft. AMH - Downstream Manhole, Survey Ends - 21 1015

Observations (24)

DistanceCodeObservation
161.8TFC
0VC
263.2TFC
106.7TFC
0MWM
0MGOCONNECTION AT THE MH 3 OC'LOCK
156.9TFC
56.7TFC
0MGOCONNECTION AT THE MH 9 OC'LOCK
0AMH21 1016
314.2VC
303.5TFC
208.3TFC
211.9TFC
167.6TBA
10.7TFC
314.2MGOCONNECTION AT THE MH 3 OC'LOCK
314.2AMH21 1015
258TB
111.3TFC
61.7TFC
0MWL
15.8TFC
308.5TFC

Properties (5)

additional_info
SC226239
custom_field_two
4
customer
LACSD
datetime
2016-04-25T23:08:03-07:00
sewer_category
GRAVITY