Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Sep 15, 2017, 06:09 AM
  • 32 0133_32 0132A_14092017_231644.mp4

Date
09/14/2017
W/O
658035
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00887
PipeID
P19881
Time
11:09 PM
Certificate
U-508-7069
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K4875
Sewer Name
32 DISTRICT #32 MAIN TRUNK
City
SANTA CLARITA
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 32
Page No.
09
Purpose
Routine Assessment
Project
WO_658035_TV32048_SEP2017
Material
NRCP
Shape
Circular
Height
18 in.
Width
18 in.
Upstream MH
32 0133
Downstream MH
32 0132A
Dir. of Survey
Downstream
Length Surveyed
74.6 ft.
Total Length
74.6 ft.
Structural Index
2
Structural Quick
322B
Structural Rating
32
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
2
Overall Quick
Overall Rating
32
Pipe schematic from manhole 32 0133 to 32 0132A
MH: 32 0133MH: 32 0132Adownstream0 ft. AMH - Upstream Manhole, Survey Begins - 32 01330 ft. MWL - Water Level, 20 %of cross sectional area0 ft. MWM - Water Mark, 30 %of cross sectional area2.1 ft. SAP - Surface Aggregate Projecting, from 07 to 05 o'clock, within 8 inches of joint: YES, Start10.6 ft. SSS - Surface Spalling, from 09 to 03 o'clock, within 8 inches of joint: YES, Start74 ft. MGO - General Observation - POSSIBLE BROKEN SHELF AT THE CONNECTION @ 09 O'CLOCK74.6 ft. AMH - Downstream Manhole, Survey Ends - 32 0132A74.6 ft. SAP - Surface Aggregate Projecting, from 07 to 05 o'clock, within 8 inches of joint: YES, Finish74.6 ft. MGO - General Observation - CONNECTION AT MH 9 O'CLOCK74.6 ft. SSS - Surface Spalling, from 09 to 03 o'clock, within 8 inches of joint: YES, Finish

Observation photos (2)

  • Surface Aggregate Projecting, from 07 to 05 o'clock, within 8 inches of joint: YES, Start

    2.1 ft. - Surface Aggregate Projecting, from 07 to 05 o'clock, within 8 inches of joint: YES, Start

  • Surface Spalling, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

    10.6 ft. - Surface Spalling, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

Observations (10)

DistanceCodeObservation
74MGOPOSSIBLE BROKEN SHELF AT THE CONNECTION @ 09 O'CLOCK
0AMH32 0133
10.6SSS
0MWL
74.6AMH32 0132A
74.6SAP
2.1SAP
74.6MGOCONNECTION AT MH 9 O'CLOCK
0MWM
74.6SSS

Properties (5)

additional_info
SC345934
custom_field_two
2
customer
LACSD
datetime
2017-09-14T23:09:29-07:00
sewer_category