- Date
- 09/18/2017
- W/O
- 657825
- Weather
- Dry
- Operator/Surveyor
- JUAN B
- Sewer ID
- Z00798
- PipeID
- P17246
- Time
- 1:41 AM
- Certificate
- U-715-07000770
- System Owner
- LACSD
- Date Cleaned
- —
- Pre-Cleaning
- Not Known
- Media Label
- K4974
- Sewer Name
- 22 CONEY TRUNK, SECTION 1
- City
- AZUSA
- Loc. details
- Main Highway - Urban
- Location Code
- A
- Use of Sewer
- Sanitary Sewer
- District
- District 22
- Page No.
- 11
- Purpose
- Routine Assessment
- Project
- WO_657825_TV22103_SEP2017
- Material
- Reinforced Concrete Pipe
- Shape
- Circular
- Height
- 15 in.
- Width
- 15 in.
- Upstream MH
- 22 0877
- Downstream MH
- 22 0876
- Dir. of Survey
- Downstream
- Length Surveyed
- 322.2 ft.
- Total Length
- 322.2 ft.
- Structural Index
- 0
- Structural Quick
- 0000
- Structural Rating
- 0
- O&M Index
- 2
- O&M Quick
- 2100
- O&M Rating
- 2
- Overall Index
- 2
- Overall Quick
- —
- Overall Rating
- 2
Pipe schematic from manhole 22 0877 to 22 0876 Observation photos (1)

2.8 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 05 to 07 o'clock, , within 8 inches of joint: YES, Start