Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Apr 8, 2015, 07:50 AM
  • 14 0083_14 0082_08042015_020812.mp4

Date
04/08/2015
W/O
497182
Weather
Dry
Operator/Surveyor
N.ZAHREDDINE
Sewer ID
Z00577
PipeID
P18098
Time
12:50 AM
Certificate
U-109-7948
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K2464
Sewer Name
14 TRUNK "A"
City
LANCASTER
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 14
Page No.
08
Purpose
Routine Assessment
Project
WO_497182_TV14018_2015MARCH
Material
Reinforced Concrete Pipe
Shape
Circular
Height
18 in.
Upstream MH
14 0083
Downstream MH
14 0082
Dir. of Survey
Downstream
Length Surveyed
447.3 ft.
Total Length
447.3 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
4
O&M Quick
4100
O&M Rating
4
Overall Index
4
Overall Quick
Overall Rating
4
Pipe schematic from manhole 14 0083 to 14 0082
MH: 14 0083MH: 14 0082downstream0 ft. MWL - Water Level, 25 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 14 00830 ft. MWM - Water Mark, 50 %of cross sectional area0 ft. MGO - General Observation - CONNECTION AT THE MH 3 O' CLOCK2 ft. MGO - General Observation - Magnesium hydroxide coating 40% start99.9 ft. TBA - Tap Break-In Active, at 10 o'clock, -, within 8 inches of joint: YES, 8"444.3 ft. MGO - General Observation - Magnesium hydroxide coating 40% finish447.3 ft. AMH - Downstream Manhole, Survey Ends - 14 0082

Observation photos (1)

  • Tap Break-In Active, at 10 o'clock, -, within 8 inches of joint: YES, 8"

    99.9 ft. - Tap Break-In Active, at 10 o'clock, -, within 8 inches of joint: YES, 8"

Observations (8)

DistanceCodeObservation
0MWL
0AMH14 0083
99.9TBA
447.3AMH14 0082
444.3MGOMagnesium hydroxide coating 40% finish
0MWM
2MGOMagnesium hydroxide coating 40% start
0MGOCONNECTION AT THE MH 3 O' CLOCK

Properties (5)

additional_info
SC207749
custom_field_two
4
customer
LACSD
datetime
2015-04-08T00:50:50-07:00
sewer_category