- Date
- 04/09/2015
- W/O
- 497182
- Weather
- Dry
- Operator/Surveyor
- N.ZAHREDDINE
- Sewer ID
- Z00577
- PipeID
- P18084
- Time
- 12:28 AM
- Certificate
- U-109-7948
- System Owner
- LACSD
- Date Cleaned
- —
- Pre-Cleaning
- Not Known
- Media Label
- K2465
- Sewer Name
- 14 TRUNK "A"
- City
- LANCASTER
- Loc. details
- Light Highway
- Location Code
- C
- Use of Sewer
- Sanitary Sewer
- District
- District 14
- Page No.
- 04
- Purpose
- Routine Assessment
- Project
- WO_497182_TV14018_2015MARCH
- Material
- Reinforced Concrete Pipe
- Shape
- Circular
- Height
- 18 in.
- Upstream MH
- 14 0070
- Downstream MH
- 14 0069
- Dir. of Survey
- Downstream
- Length Surveyed
- 450.1 ft.
- Total Length
- 450.1 ft.
- Structural Index
- 3
- Structural Quick
- 3200
- Structural Rating
- 6
- O&M Index
- 4
- O&M Quick
- 4100
- O&M Rating
- 4
- Overall Index
- 3
- Overall Quick
- —
- Overall Rating
- 10
Pipe schematic from manhole 14 0070 to 14 0069 Observation photos (4)

5.8 ft. - Surface Aggregate Visible, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

258.7 ft. - Tap Break-In Active, at 02 o'clock, -, within 8 inches of joint: YES, 6"

379.8 ft. - Tap Break-In Active, at 02 o'clock, -, within 8 inches of joint: YES, 6"

439.6 ft. - Tap Break-In Active, at 02 o'clock, -, within 8 inches of joint: YES, 6"