Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Apr 15, 2015, 07:17 AM
  • 14 0058_14 0057_15042015_014730.mp4

Date
04/15/2015
W/O
497182
Weather
Dry
Operator/Surveyor
N.ZAHREDDINE
Sewer ID
Z00577
PipeID
P18070
Time
12:17 AM
Certificate
U-109-7948
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K2469
Sewer Name
14 TRUNK "A"
City
LANCASTER
Loc. details
Easement/Right of Way
Location Code
D
Use of Sewer
Sanitary Sewer
District
District 14
Page No.
04
Purpose
Routine Assessment
Project
WO_497182_TV14018_2015MARCH
Material
Reinforced Concrete Pipe
Shape
Circular
Height
24 in.
Upstream MH
14 0058
Downstream MH
14 0057
Dir. of Survey
Downstream
Length Surveyed
417.9 ft.
Total Length
417.9 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
4
O&M Quick
4100
O&M Rating
4
Overall Index
4
Overall Quick
Overall Rating
4
Pipe schematic from manhole 14 0058 to 14 0057
MH: 14 0058MH: 14 0057downstream0 ft. MWL - Water Level, 25 %of cross sectional area0 ft. MWM - Water Mark, 50 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 14 00582 ft. MGO - General Observation - Magnesium hydroxide coating 40% start11.7 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 6"36 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: YES, 6"59.6 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 6"83.5 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: YES, 6"132 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: YES, 6"156.2 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 6"180.1 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: YES, 6"203.8 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 6"227.3 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: YES, 6"251.7 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 6"275.9 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: YES, 6"300.1 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 6"323.5 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: YES, 6"347.6 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 6"370.9 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: YES, 6"395.2 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 6"415.2 ft. MGO - General Observation - Magnesium hydroxide coating 40% finish417.9 ft. AMH - Downstream Manhole, Survey Ends - 14 0057

Observations (22)

DistanceCodeObservation
203.8TFC
227.3TFC
323.5TFC
415.2MGOMagnesium hydroxide coating 40% finish
83.5TFC
0MWL
2MGOMagnesium hydroxide coating 40% start
251.7TFC
59.6TFC
36TFC
370.9TFC
156.2TFC
180.1TFC
275.9TFC
395.2TFC
0MWM
11.7TFC
132TFC
0AMH14 0058
300.1TFC
417.9AMH14 0057
347.6TFC

Properties (5)

additional_info
SC201205
custom_field_two
4
customer
LACSD
datetime
2015-04-15T00:17:36-07:00
sewer_category
GRAVITY