- Date
- 04/09/2015
- W/O
- 497182
- Weather
- Dry
- Operator/Surveyor
- N.ZAHREDDINE
- Sewer ID
- Z00577
- PipeID
- P18081
- Time
- 1:25 AM
- Certificate
- U-109-7948
- System Owner
- LACSD
- Date Cleaned
- —
- Pre-Cleaning
- Not Known
- Media Label
- K2465
- Sewer Name
- 14 TRUNK "A"
- City
- LANCASTER
- Loc. details
- Light Highway
- Location Code
- C
- Use of Sewer
- Sanitary Sewer
- District
- District 14
- Page No.
- 04
- Purpose
- Routine Assessment
- Project
- WO_497182_TV14018_2015MARCH
- Material
- Reinforced Concrete Pipe
- Shape
- Circular
- Height
- 18 in.
- Upstream MH
- 14 0068A
- Downstream MH
- 14 0068
- Dir. of Survey
- Downstream
- Length Surveyed
- 104.9 ft.
- Total Length
- 104.9 ft.
- Structural Index
- 0
- Structural Quick
- 0000
- Structural Rating
- 0
- O&M Index
- 3
- O&M Quick
- 4121
- O&M Rating
- 6
- Overall Index
- 3
- Overall Quick
- —
- Overall Rating
- 6
Pipe schematic from manhole 14 0068A to 14 0068 Observation photos (2)

15.3 ft. - Tap Break-In Intruding, at 10 o'clock, -, #v, within 8 inches of joint: YES, 6", 2"

79.9 ft. - Tap Break-In Active, at 10 o'clock, -, within 8 inches of joint: YES, 6"