Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Dec 30, 2014, 07:59 AM
  • 22 0229_22 0228_20141230_001257.mp4

Date
12/29/2014
W/O
481935
Weather
Dry
Operator/Surveyor
ERU
Sewer ID
Z00793
PipeID
P16510
Time
11:59 PM
Certificate
123456
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K1998
Sewer Name
22 CAMERON TRUNK, SECTS 1,2,&3
City
WEST COVINA
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 22
Page No.
35
Purpose
Routine Assessment
Project
WO_481935_TV22017_2014DECEMBER
Material
Reinforced Concrete Pipe
Shape
Circular
Height
21 in.
Upstream MH
22 0229
Downstream MH
22 0228
Dir. of Survey
Downstream
Length Surveyed
201.2 ft.
Total Length
201.2 ft.
Structural Index
3
Structural Quick
3G00
Structural Rating
114
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
114
Pipe schematic from manhole 22 0229 to 22 0228
MH: 22 0229MH: 22 0228downstream0 ft. MWL - Water Level, 25 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 00000 ft. MWM - Water Mark, 35 %of cross sectional area0 ft. TFA - Tap Factory Made Active, at 03 o'clock, -, within 8 inches of joint: YES, 15"4.9 ft. MGO - General Observation - MAG COATING THROUGHOUT PIPE21.5 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: YES, 6"33.7 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 6"69.7 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: YES, 6"82.5 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 6"130.1 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 6"166 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: YES, 6"177.9 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 6"201.2 ft. AMH - Downstream Manhole, Survey Ends - 0012

Observation photos (1)

  • General Observation - MAG COATING THROUGHOUT PIPE

    4.9 ft. - General Observation - MAG COATING THROUGHOUT PIPE

Observations (13)

DistanceCodeObservation
33.7TFC
177.9TFC
0MWL
201.2AMH0012
82.5TFC
130.1TFC
166TF
21.5TFC
69.7TFC
4.9MGOMAG COATING THROUGHOUT PIPE
0AMH0000
0MWM
0TFA

Properties (5)

additional_info
SC189563
custom_field_two
4
customer
LACSD
datetime
2014-12-29T23:59:06-08:00
sewer_category
GRAVITY