Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Dec 30, 2014, 09:03 AM
  • 22 0233_22 0232_20141230_012207.mp4

Date
12/30/2014
W/O
481935
Weather
Dry
Operator/Surveyor
ERU
Sewer ID
Z00793
PipeID
P16514
Time
1:03 AM
Certificate
123456
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K1998
Sewer Name
22 CAMERON TRUNK, SECTS 1,2,&3
City
WEST COVINA
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 22
Page No.
35
Purpose
Routine Assessment
Project
WO_481935_TV22017_2014DECEMBER
Material
Reinforced Concrete Pipe
Shape
Circular
Height
21 in.
Upstream MH
22 0232
Downstream MH
22 0233
Dir. of Survey
Upstream
Length Surveyed
392.4 ft.
Total Length
392.4 ft.
Structural Index
3
Structural Quick
3N00
Structural Rating
231
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
231
Pipe schematic from manhole 22 0232 to 22 0233
MH: 22 0232MH: 22 0233upstream0 ft. AMH - Upstream Manhole, Survey Ends - 01210 ft. TFA - Tap Factory Made Active, at 03 o'clock, -, within 8 inches of joint: NO, 8"0 ft. TFA - Tap Factory Made Active, at 09 o'clock, -, within 8 inches of joint: YES, 8"45.1 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: YES, 6"56.9 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: YES, 6"92.8 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: YES, 6"117 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 6"164.4 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: YES, 6"177.1 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: YES, 6"212 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: YES, 6"224.7 ft. TFA - Tap Factory Made Active, at 02 o'clock, -, within 8 inches of joint: YES, 6"260.7 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 6"272.6 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: YES, 6"307.9 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: YES, 6"321 ft. TFA - Tap Factory Made Active, at 02 o'clock, -, within 8 inches of joint: YES, 6"356.7 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: YES, 6"369.1 ft. TFA - Tap Factory Made Active, at 02 o'clock, -, within 8 inches of joint: YES, 6"386.8 ft. MGO - General Observation - MAG COATING THROUGHOUT PIPE392.4 ft. MWM - Water Mark, 40 %of cross sectional area392.4 ft. MWL - Water Level, 30 %of cross sectional area392.4 ft. AMH - Downstream Manhole, Survey Begins - 0105

Observation photos (1)

  • General Observation - MAG COATING THROUGHOUT PIPE

    5.6 ft. - General Observation - MAG COATING THROUGHOUT PIPE

Observations (21)

DistanceCodeObservation
35.7TF
215.3TFC
392.4AMH0121
0MWM
84.5TF
299.6TFC
23.3TFA
392.4TFA
180.4TF
275.4TFC
71.4TFA
167.7TFA
5.6MGOMAG COATING THROUGHOUT PIPE
228TF
392.4TFA
347.3TFC
119.8TFC
335.5TF
131.7TFC
0MWL
0AMH0105

Properties (5)

additional_info
SC189563
custom_field_two
4
customer
LACSD
datetime
2014-12-30T01:03:56-08:00
sewer_category
SIPHON