Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jan 24, 2017, 06:38 AM
  • 22 0271_22 0270_23012017_223849.mp4

Date
01/23/2017
W/O
613443
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00793
PipeID
P16556
Time
10:38 PM
Certificate
U-508-7069
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K4132
Sewer Name
22 CAMERON TRUNK, SECTS 1,2,&3
City
WEST COVINA
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 22
Page No.
36
Purpose
Routine Assessment
Project
WO_613443_TV22016_JAN2017
Material
NRCP
Shape
Circular
Height
15 in.
Width
15 in.
Upstream MH
22 0271
Downstream MH
22 0270
Dir. of Survey
Downstream
Length Surveyed
207.4 ft.
Total Length
207.4 ft.
Structural Index
3
Structural Quick
3O21
Structural Rating
242
O&M Index
3
O&M Quick
4329
O&M Rating
30
Overall Index
3
Overall Quick
Overall Rating
272
Pipe schematic from manhole 22 0271 to 22 0270
MH: 22 0271MH: 22 0270downstream0 ft. AMH - Upstream Manhole, Survey Begins - 22 02710 ft. MGO - General Observation - CONNECTION AT THE MH 6 O'CLOCK0 ft. MWM - Water Mark, 20 %of cross sectional area0 ft. MWL - Water Level, 10 %of cross sectional area2 ft. SAV - Surface Aggregate Visible, from 07 to 05 o'clock, within 8 inches of joint: YES, Start11.8 ft. SAP - Surface Aggregate Projecting, from 07 to 05 o'clock, within 8 inches of joint: YES, Start25.3 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"29.3 ft. DSZ - Deposits Settled Other, 5 %of cross sectional area, at 06 o'clock, , within 8 inches of joint: NO54 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"82.1 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"104.3 ft. CL - Crack Longitudinal, at 09 o'clock, within 8 inches of joint: YES130.9 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"159.5 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"166.7 ft. DSZ - Deposits Settled Other, 5 %of cross sectional area, at 06 o'clock, , within 8 inches of joint: NO, Start170.8 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"193.5 ft. MCU - Camera Underwater, Start207.4 ft. SAV - Surface Aggregate Visible, from 07 to 05 o'clock, within 8 inches of joint: YES, Finish207.4 ft. MSA - Survey Abandoned - CAM BLKD BY DEBRIS207.4 ft. MCU - Camera Underwater, Finish207.4 ft. DSZ - Deposits Settled Other, 5 %of cross sectional area, at 06 o'clock, , within 8 inches of joint: NO, Finish207.4 ft. SAP - Surface Aggregate Projecting, from 07 to 05 o'clock, within 8 inches of joint: YES, Finish

Observation photos (6)

  • Surface Aggregate Visible, from 07 to 05 o'clock, within 8 inches of joint: YES, Start

    2 ft. - Surface Aggregate Visible, from 07 to 05 o'clock, within 8 inches of joint: YES, Start

  • Surface Aggregate Projecting, from 07 to 05 o'clock, within 8 inches of joint: YES, Start

    11.8 ft. - Surface Aggregate Projecting, from 07 to 05 o'clock, within 8 inches of joint: YES, Start

  • Deposits Settled Other,  5 %of cross sectional area, at 06 o'clock,  , within 8 inches of joint: NO

    29.3 ft. - Deposits Settled Other, 5 %of cross sectional area, at 06 o'clock, , within 8 inches of joint: NO

  • Crack Longitudinal, at 09 o'clock, within 8 inches of joint: YES

    104.3 ft. - Crack Longitudinal, at 09 o'clock, within 8 inches of joint: YES

  • Deposits Settled Other,  5 %of cross sectional area, at 06 o'clock,  , within 8 inches of joint: NO, Start

    166.7 ft. - Deposits Settled Other, 5 %of cross sectional area, at 06 o'clock, , within 8 inches of joint: NO, Start

  • Camera Underwater, Start

    193.5 ft. - Camera Underwater, Start

Observations (21)

DistanceCodeObservation
166.7DSZ
130.9TF
170.8TFC
0AMH22 0271
207.4SAV
207.4MSACAM BLKD BY DEBRIS
104.3CL
207.4MCU
29.3DSZ
159.5TFC
207.4DSZ
2SAV
54TFC
0MGOCONNECTION AT THE MH 6 O'CLOCK
82.1TFC
11.8SAP
193.5MCU
25.3TFC
207.4SAP
0MWM
0MWL

Properties (5)

additional_info
SC306488
custom_field_two
3
customer
LACSD
datetime
2017-01-23T22:38:40-08:00
sewer_category