Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jan 24, 2017, 10:01 AM
  • 22 0265_22 0264_24012017_020137.mp4

Date
01/24/2017
W/O
613443
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00793
PipeID
P16548
Time
2:01 AM
Certificate
U-508-7069
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K4132
Sewer Name
22 CAMERON TRUNK, SECTS 1,2,&3
City
WEST COVINA
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 22
Page No.
36
Purpose
Routine Assessment
Project
WO_613443_TV22016_JAN2017
Material
NRCP
Shape
Circular
Height
15 in.
Width
15 in.
Upstream MH
22 0265
Downstream MH
22 0264
Dir. of Survey
Downstream
Length Surveyed
437.9 ft.
Total Length
437.9 ft.
Structural Index
3
Structural Quick
3P00
Structural Rating
258
O&M Index
2
O&M Quick
2212
O&M Rating
6
Overall Index
3
Overall Quick
Overall Rating
264
Pipe schematic from manhole 22 0265 to 22 0264
MH: 22 0265MH: 22 0264downstream0 ft. AMH - Upstream Manhole, Survey Begins - 22 02650 ft. MWM - Water Mark, 20 %of cross sectional area0 ft. MWL - Water Level, 10 %of cross sectional area2.4 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start10.3 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"36.5 ft. RFJ - Roots Fine Joint, at 10 o'clock, within 8 inches of joint: YESR50.2 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"58.1 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"106.3 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: YES, 6"108.1 ft. RFJ - Roots Fine Joint, at 12 o'clock, within 8 inches of joint: YESR110.2 ft. TFA - Tap Factory Made Active, at 10 o'clock, -, within 8 inches of joint: NO, 6"129.7 ft. RFB - Roots Fine Barrell, at 12 o'clock, within 8 inches of joint: NO140 ft. TB - Tap Break-In, at 10 o'clock, -, within 8 inches of joint: NO, 6"142.5 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"159 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"215.2 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"249 ft. TBI - Tap Break-In Intruding, at 10 o'clock, -, #v, within 8 inches of joint: NO, 6", 1"259.6 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"307.9 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"316.2 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"360.1 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"379.9 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"408.4 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"434.5 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish434.5 ft. MMC - Material Change, Vitrified clay pipe437.9 ft. MGO - General Observation - CONNECTION AT THE MH 9 O'CLOCK437.9 ft. AMH - Downstream Manhole, Survey Ends - 22 0264

Observation photos (7)

  • Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2.4 ft. - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Roots Fine Joint, at 10 o'clock, within 8 inches of joint: YESR

    36.5 ft. - Roots Fine Joint, at 10 o'clock, within 8 inches of joint: YESR

  • Roots Fine Joint, at 12 o'clock, within 8 inches of joint: YESR

    108.1 ft. - Roots Fine Joint, at 12 o'clock, within 8 inches of joint: YESR

  • Roots Fine Barrell, at 12 o'clock, within 8 inches of joint: NO

    129.7 ft. - Roots Fine Barrell, at 12 o'clock, within 8 inches of joint: NO

  • Tap Break-In, at 10 o'clock, -, within 8 inches of joint: NO, 6"

    140 ft. - Tap Break-In, at 10 o'clock, -, within 8 inches of joint: NO, 6"

  • Tap Break-In Intruding, at 10 o'clock, -, #v, within 8 inches of joint: NO, 6", 1"

    249 ft. - Tap Break-In Intruding, at 10 o'clock, -, #v, within 8 inches of joint: NO, 6", 1"

  • Material Change, Vitrified clay pipe

    434.5 ft. - Material Change, Vitrified clay pipe

Observations (27)

DistanceCodeObservation
140TB
307.9TFC
259.6TFC
434.5SAP
360.1TF
2.4SAP
0AMH22 0265
434.5MMC
50.2TFC
0MWM
159TFC
437.9MGOCONNECTION AT THE MH 9 O'CLOCK
58.1TFC
106.3TFC
0MWL
110.2TFA
36.5RFJ
129.7RFB
215.2TFC
142.5TFC
408.4TFC
437.9AMH22 0264
10.3TF
108.1RFJ
316.2TF
249TBI
379.9TFC

Properties (5)

additional_info
SC306488
custom_field_two
3
customer
LACSD
datetime
2017-01-24T02:01:07-08:00
sewer_category
Gravity