Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jan 24, 2017, 08:04 AM
  • 22 0269_22 1388_24012017_000639.mp4

Date
01/24/2017
W/O
613443
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00793
PipeID
P16554
Time
12:04 AM
Certificate
U-508-7069
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K4132
Sewer Name
22 CAMERON TRUNK, SECTS 1,2,&3
City
WEST COVINA
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 22
Page No.
36
Purpose
Routine Assessment
Project
WO_613443_TV22016_JAN2017
Material
NRCP
Shape
Circular
Height
15 in.
Width
15 in.
Upstream MH
22 1388
Downstream MH
22 0269
Dir. of Survey
Upstream
Length Surveyed
121.3 ft.
Total Length
121.3 ft.
Structural Index
3
Structural Quick
3D00
Structural Rating
72
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
72
Pipe schematic from manhole 22 1388 to 22 0269
MH: 22 1388MH: 22 0269upstream0 ft. SAP - Surface Aggregate Projecting, from 07 to 05 o'clock, within 8 inches of joint: YES, Finish0 ft. AMH - Upstream Manhole, Survey Ends - 22 02690 ft. MGO - General Observation - CONNECTION AT THE MH 3 O'CLOCK13.8 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"38.1 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"62.3 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"90.4 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"114.5 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"119.3 ft. SAP - Surface Aggregate Projecting, from 07 to 05 o'clock, within 8 inches of joint: YES, Start121.3 ft. AMH - Downstream Manhole, Survey Begins - 22 1388121.3 ft. MWL - Water Level, 20 %of cross sectional area121.3 ft. MWM - Water Mark, 25 %of cross sectional area121.3 ft. MGO - General Observation - CONNECTION AT THE MH 6 O'CLOCK121.3 ft. MGO - General Observation - CONNECTION AT THE MH 3 O'CLOCK

Observation photos (1)

  • Surface Aggregate Projecting, from 07 to 05 o'clock, within 8 inches of joint: YES, Start

    2 ft. - Surface Aggregate Projecting, from 07 to 05 o'clock, within 8 inches of joint: YES, Start

Observations (14)

DistanceCodeObservation
121.3SAP
0AMH22 1388
0MWL
59TFC
107.5TFC
6.8TFC
0MWM
2SAP
121.3AMH22 0269
0MGOCONNECTION AT THE MH 6 O'CLOCK
30.9TFC
83.2TFC
0MGOCONNECTION AT THE MH 3 O'CLOCK
121.3MGOCONNECTION AT THE MH 3 O'CLOCK

Properties (4)

custom_field_two
3
customer
LACSD
datetime
2017-01-24T00:04:09-08:00
sewer_category
Gravity