Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jan 25, 2017, 08:21 AM
  • 22 0253_22 0252_25012017_002152.mp4

Date
01/25/2017
W/O
613443
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00793
PipeID
P16535
Time
12:21 AM
Certificate
U-508-7069
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K4133
Sewer Name
22 CAMERON TRUNK, SECTS 1,2,&3
City
WEST COVINA
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 22
Page No.
36
Purpose
Routine Assessment
Project
WO_613443_TV22016_JAN2017
Material
NRCP
Shape
Circular
Height
15 in.
Width
15 in.
Upstream MH
22 0253
Downstream MH
22 0252
Dir. of Survey
Downstream
Length Surveyed
359.2 ft.
Total Length
359.2 ft.
Structural Index
3
Structural Quick
3M11
Structural Rating
214
O&M Index
1
O&M Quick
2112
O&M Rating
4
Overall Index
3
Overall Quick
Overall Rating
218
Pipe schematic from manhole 22 0253 to 22 0252
MH: 22 0253MH: 22 0252downstream0 ft. MGO - General Observation - CONNECTION AT THE MH 9 O'CLOCK0 ft. AMH - Upstream Manhole, Survey Begins - 22 02530 ft. MGO - General Observation - CONNECTION AT THE MH 3 O'CLOCK0 ft. MWM - Water Mark, 30 %of cross sectional area0 ft. MWL - Water Level, 15 %of cross sectional area3.1 ft. SAP - Surface Aggregate Projecting, from 07 to 05 o'clock, within 8 inches of joint: YES, Start7.3 ft. CC - Crack Circumferential, from 01 to 04 o'clock, within 8 inches of joint: YES64.3 ft. RFJ - Roots Fine Joint, at 10 o'clock, within 8 inches of joint: YESR83.8 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"132.5 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"141.3 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"180.5 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"231.6 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"231.6 ft. RFL - Roots Fine Lateral, at 09 o'clock268.4 ft. RFB - Roots Fine Barrell, at 10 o'clock, within 8 inches of joint: NO279.8 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"283 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"345.7 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"356.8 ft. SAP - Surface Aggregate Projecting, from 07 to 05 o'clock, within 8 inches of joint: YES, Finish359.2 ft. MGO - General Observation - CONNECTION AT THE MH 3 O'CLOCK359.2 ft. AMH - Downstream Manhole, Survey Ends - 22 0252

Observation photos (4)

  • Surface Aggregate Projecting, from 07 to 05 o'clock, within 8 inches of joint: YES, Start

    3.1 ft. - Surface Aggregate Projecting, from 07 to 05 o'clock, within 8 inches of joint: YES, Start

  • Crack Circumferential, from 01 to 04 o'clock, within 8 inches of joint: YES

    7.3 ft. - Crack Circumferential, from 01 to 04 o'clock, within 8 inches of joint: YES

  • Roots Fine Joint, at 10 o'clock, within 8 inches of joint: YESR

    64.3 ft. - Roots Fine Joint, at 10 o'clock, within 8 inches of joint: YESR

  • Roots Fine Barrell, at 10 o'clock, within 8 inches of joint: NO

    268.4 ft. - Roots Fine Barrell, at 10 o'clock, within 8 inches of joint: NO

Observations (21)

DistanceCodeObservation
0MGOCONNECTION AT THE MH 9 O'CLOCK
141.3TF
0AMH22 0253
64.3RFJ
345.7TF
132.5TFC
3.1SAP
231.6TF
283TFC
7.3CC
359.2MGOCONNECTION AT THE MH 3 O'CLOCK
180.5TFC
0MGOCONNECTION AT THE MH 3 O'CLOCK
279.8TFC
231.6RFL
0MWM
356.8SAP
83.8TFC
0MWL
359.2AMH22 0252
268.4RFB

Properties (5)

additional_info
SC306489
custom_field_two
3
customer
LACSD
datetime
2017-01-25T00:21:18-08:00
sewer_category