- Date
- 01/24/2017
- W/O
- 613443
- Weather
- Dry
- Operator/Surveyor
- B.FUGATE
- Sewer ID
- Z00793
- PipeID
- P16540
- Time
- 10:57 PM
- Certificate
- U-508-7069
- System Owner
- LACSD
- Date Cleaned
- —
- Pre-Cleaning
- No Pre-Cleaning
- Media Label
- K4133
- Sewer Name
- 22 CAMERON TRUNK, SECTS 1,2,&3
- City
- WEST COVINA
- Loc. details
- Main Highway - Urban
- Location Code
- A
- Use of Sewer
- Sanitary Sewer
- District
- District 22
- Page No.
- 36
- Purpose
- Routine Assessment
- Project
- WO_613443_TV22016_JAN2017
- Material
- NRCP
- Shape
- Circular
- Height
- 15 in.
- Width
- 15 in.
- Upstream MH
- 22 0258
- Downstream MH
- 22 0257
- Dir. of Survey
- Downstream
- Length Surveyed
- 386.6 ft.
- Total Length
- 386.6 ft.
- Structural Index
- 3
- Structural Quick
- 3N00
- Structural Rating
- 231
- O&M Index
- 1
- O&M Quick
- 2213
- O&M Rating
- 7
- Overall Index
- 3
- Overall Quick
- —
- Overall Rating
- 238
Pipe schematic from manhole 22 0258 to 22 0257 Observation photos (5)

2.3 ft. - Surface Aggregate Projecting, from 07 to 05 o'clock, within 8 inches of joint: YES, Start

82.8 ft. - Roots Fine Barrell, at 12 o'clock, within 8 inches of joint: NO

111.8 ft. - Roots Fine Barrell, at 12 o'clock, within 8 inches of joint: NO

349.5 ft. - Roots Fine Joint, from 02 to 04 o'clock, within 8 inches of joint: YESR

367.1 ft. - Roots Fine Joint, from 07 to 12 o'clock, within 8 inches of joint: YESR