Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jan 24, 2017, 09:16 AM
  • 22 0267_22 0266_24012017_011639.mp4

Date
01/24/2017
W/O
613443
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00793
PipeID
P16550
Time
1:16 AM
Certificate
U-508-7069
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K4132
Sewer Name
22 CAMERON TRUNK, SECTS 1,2,&3
City
WEST COVINA
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 22
Page No.
36
Purpose
Routine Assessment
Project
WO_613443_TV22016_JAN2017
Material
NRCP
Shape
Circular
Height
15 in.
Width
15 in.
Upstream MH
22 0266
Downstream MH
22 0267
Dir. of Survey
Upstream
Length Surveyed
430.1 ft.
Total Length
430.1 ft.
Structural Index
3
Structural Quick
513Q
Structural Rating
269
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
269
Pipe schematic from manhole 22 0266 to 22 0267
MH: 22 0266MH: 22 0267upstream0 ft. AMH - Upstream Manhole, Survey Ends - 22 02670 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish9.1 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"51.8 ft. CM - Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES56.8 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"60.7 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"104.9 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"109 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"151.9 ft. CM - Crack Multiple, from 09 to 10 o'clock, within 8 inches of joint: YES157.2 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"208.9 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"253.1 ft. TFA - Tap Factory Made Active, at 02 o'clock, -, within 8 inches of joint: NO, 6"261 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"264.4 ft. HVV - Hole Void Visible, from 09 to 11 o'clock, within 8 inches of joint: YES293.4 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"321.4 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"377.5 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"393.9 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"422.1 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"428.1 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start430.1 ft. MWM - Water Mark, 25 %of cross sectional area430.1 ft. AMH - Downstream Manhole, Survey Begins - 22 0266430.1 ft. MWL - Water Level, 20 %of cross sectional area

Observation photos (4)

  • Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2 ft. - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Hole Void Visible, from 09 to 11 o'clock, within 8 inches of joint: YES

    165.7 ft. - Hole Void Visible, from 09 to 11 o'clock, within 8 inches of joint: YES

  • Crack Multiple, from 09 to 10 o'clock, within 8 inches of joint: YES

    278.2 ft. - Crack Multiple, from 09 to 10 o'clock, within 8 inches of joint: YES

  • Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES

    378.3 ft. - Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES

Observations (23)

DistanceCodeObservation
278.2CM
369.4TF
373.3TFC
0MWM
136.7TF
378.3CM
421TFC
325.2TF
108.7TFC
177TFA
169.1TFC
272.9TFC
36.2TF
321.1TFC
221.2TFC
430.1AMH22 0267
2SAP
165.7HVV
0AMH22 0266
52.6TFC
430.1SAP
8TFC
0MWL

Properties (5)

additional_info
SC306488
custom_field_two
1
customer
LACSD
datetime
2017-01-24T01:16:21-08:00
sewer_category
Gravity