Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jan 25, 2017, 07:55 AM
  • 22 0256_22 0255 _24012017_235608.mp4

Date
01/24/2017
W/O
613443
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00793
PipeID
P16538
Time
11:55 PM
Certificate
U-508-7069
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K4133
Sewer Name
22 CAMERON TRUNK, SECTS 1,2,&3
City
WEST COVINA
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 22
Page No.
36
Purpose
Routine Assessment
Project
WO_613443_TV22016_JAN2017
Material
NRCP
Shape
Circular
Height
15 in.
Width
15 in.
Upstream MH
22 0256
Downstream MH
22 0255
Dir. of Survey
Downstream
Length Surveyed
152.6 ft.
Total Length
152.6 ft.
Structural Index
3
Structural Quick
3E00
Structural Rating
90
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
90
Pipe schematic from manhole 22 0256 to 22 0255
MH: 22 0256MH: 22 0255downstream0 ft. AMH - Upstream Manhole, Survey Begins - 22 02560 ft. MWM - Water Mark, 30 %of cross sectional area0 ft. MWL - Water Level, 20 %of cross sectional area0.1 ft. MGO - General Observation - CONNECTION AT THE MH 9 O'CLOCK2 ft. SAP - Surface Aggregate Projecting, from 07 to 05 o'clock, within 8 inches of joint: YES, Start14.9 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"18.1 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"63.7 ft. TB - Tap Break-In, at 02 o'clock, -, within 8 inches of joint: NO, 6"69.5 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"84.7 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"108.9 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"139.1 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"152.6 ft. AMH - Downstream Manhole, Survey Ends - 22 0255152.6 ft. SAP - Surface Aggregate Projecting, from 07 to 05 o'clock, within 8 inches of joint: YES, Finish

Observation photos (2)

  • Surface Aggregate Projecting, from 07 to 05 o'clock, within 8 inches of joint: YES, Start

    2 ft. - Surface Aggregate Projecting, from 07 to 05 o'clock, within 8 inches of joint: YES, Start

  • Tap Break-In, at 02 o'clock, -, within 8 inches of joint: NO, 6"

    63.7 ft. - Tap Break-In, at 02 o'clock, -, within 8 inches of joint: NO, 6"

Observations (14)

DistanceCodeObservation
0AMH22 0256
69.5TFC
84.7TFC
152.6AMH22 0255
0.1MGOCONNECTION AT THE MH 9 O'CLOCK
139.1TF
152.6SAP
63.7TB
2SAP
0MWM
108.9TFC
18.1TF
14.9TFC
0MWL

Properties (5)

additional_info
SC306489
custom_field_two
3
customer
LACSD
datetime
2017-01-24T23:55:39-08:00
sewer_category
Gravity