Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Sep 1, 2017, 05:16 AM
  • 19 0275_19 0274 _31082017_224803.mp4

Date
08/31/2017
W/O
651801
Weather
Dry
Operator/Surveyor
JUAN B
Sewer ID
Z00732
PipeID
P15245
Time
10:16 PM
Certificate
U-715-07000770
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K4704
Sewer Name
19 209TH STREET TRUNK
City
LAKEWOOD
Loc. details
Easement/Right of Way
Location Code
D
Use of Sewer
Sanitary Sewer
District
District 19
Page No.
07
Purpose
Routine Assessment
Project
WO_651801_TV19001_AUG2017
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
10 in.
Width
10 in.
Upstream MH
19 0275
Downstream MH
19 0274
Dir. of Survey
Downstream
Length Surveyed
408 ft.
Total Length
408 ft.
Structural Index
3
Structural Quick
4233
Structural Rating
17
O&M Index
2
O&M Quick
2211
O&M Rating
5
Overall Index
3
Overall Quick
Overall Rating
22
Pipe schematic from manhole 19 0275 to 19 0274
MH: 19 0275MH: 19 0274downstream0 ft. MWM - Water Mark, 20 %of cross sectional area0 ft. MWL - Water Level, 15 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 19 02753.9 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start3.9 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start15.8 ft. LR - Alignment Right, 5 %35.6 ft. TFC - Tap Factory Made Capped, at 03 o'clock, -, within 8 inches of joint: NO, 4"44.7 ft. TB - Tap Break-In, at 02 o'clock, -, within 8 inches of joint: NO, 4"62.3 ft. B - Broken, from 09 to 10 o'clock, within 8 inches of joint: YES63 ft. TF - Tap Factory Made, at 09 o'clock, -, within 8 inches of joint: NO, 4"65.2 ft. FS - Fracture Spiral, from 09 to 03 o'clock, within 8 inches of joint: YES84.4 ft. TFC - Tap Factory Made Capped, at 03 o'clock, -, within 8 inches of joint: NO, 4"87.7 ft. TFC - Tap Factory Made Capped, at 09 o'clock, -, within 8 inches of joint: NO, 4"92.3 ft. FS - Fracture Spiral, from 09 to 10 o'clock, within 8 inches of joint: NO131.9 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish131.9 ft. FM - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start135.9 ft. TFA - Tap Factory Made Active, at 03 o'clock, -, within 8 inches of joint: NO, 4"138.9 ft. TFC - Tap Factory Made Capped, at 09 o'clock, -, within 8 inches of joint: NO, 4"185.8 ft. TFC - Tap Factory Made Capped, at 03 o'clock, -, within 8 inches of joint: NO, 4"187.5 ft. TF - Tap Factory Made, at 09 o'clock, -, within 8 inches of joint: NO, 4"236 ft. TFC - Tap Factory Made Capped, at 03 o'clock, -, within 8 inches of joint: NO, 4"239.1 ft. TFC - Tap Factory Made Capped, at 09 o'clock, -, within 8 inches of joint: NO, 4"284.4 ft. TFC - Tap Factory Made Capped, at 03 o'clock, -, within 8 inches of joint: NO, 4"287.5 ft. TF - Tap Factory Made, at 09 o'clock, -, within 8 inches of joint: NO, 4"336.1 ft. TFC - Tap Factory Made Capped, at 03 o'clock, -, within 8 inches of joint: NO, 4"339.3 ft. TFA - Tap Factory Made Active, at 09 o'clock, -, within 8 inches of joint: NO, 4"362.4 ft. DAE - Deposits Attached Encrustation, 5 %of cross sectional area, from 08 to 04 o'clock, , within 8 inches of joint: YES, Start384.8 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 4"387.6 ft. TFC - Tap Factory Made Capped, at 09 o'clock, -, within 8 inches of joint: NO, 4"407.7 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish407.8 ft. DAE - Deposits Attached Encrustation, 5 %of cross sectional area, from 08 to 04 o'clock, , within 8 inches of joint: YES, Finish407.8 ft. FM - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish408 ft. AMH - Downstream Manhole, Survey Ends - 19 0274

Observation photos (7)

  • Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock,  , within 8 inches of joint: YES, Start

    3.9 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start

  • Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    3.9 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Broken, from 09 to 10 o'clock, within 8 inches of joint: YES

    62.3 ft. - Broken, from 09 to 10 o'clock, within 8 inches of joint: YES

  • Fracture Spiral, from 09 to 03 o'clock, within 8 inches of joint: YES

    65.2 ft. - Fracture Spiral, from 09 to 03 o'clock, within 8 inches of joint: YES

  • Fracture Spiral, from 09 to 10 o'clock, within 8 inches of joint: NO

    92.3 ft. - Fracture Spiral, from 09 to 10 o'clock, within 8 inches of joint: NO

  • Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    131.9 ft. - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Deposits Attached Encrustation, 5 %of cross sectional area, from 08 to 04 o'clock,  , within 8 inches of joint: YES, Start

    362.4 ft. - Deposits Attached Encrustation, 5 %of cross sectional area, from 08 to 04 o'clock, , within 8 inches of joint: YES, Start

Observations (33)

DistanceCodeObservation
92.3FS
44.7TB
284.4TFC
0MWM
185.8TFC
362.4DAE
84.4TFC
408AMH19 0274
287.5TF
15.8LR
131.9CM
407.8DAE
3.9DAGS
87.7TFC
3.9CM
384.8TF
387.6TFC
63TF
0MWL
135.9TFA
339.3TFA
187.5TF
236TFC
239.1TFC
0AMH19 0275
65.2FS
62.3B
131.9FM
138.9TFC
407.7DAGS
35.6TFC
336.1TFC
407.8FM

Properties (4)

additional_info
SC345645
custom_field_two
3
customer
LACSD
datetime
2017-08-31T22:16:05-07:00