Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Oct 10, 2017, 10:01 AM
  • Section#3_05 1843_05 1842__10102017__G6846.mp4

Date
10/10/2017
W/O
#
Weather
Dry
Operator/Surveyor
MARTIN
Sewer ID
Z00494
PipeID
P07067
Time
3:01 AM
Certificate
U-1014-06022543
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
G6846
Sewer Name
05 NORTH SLOPE CONNECTION TRUNK
City
LOMITA
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 05
Page No.
35
Purpose
Routine Assessment
Project
20171010MDM_NORTH_SLOPE_CONNECTION_TRUNK
Material
Vitrified Clay Pipe
Shape
Circular
Height
18 in.
Upstream MH
05 1843
Downstream MH
05 1842
Dir. of Survey
Downstream
Length Surveyed
494.4 ft.
Total Length
494.4 ft.
Structural Index
2
Structural Quick
2100
Structural Rating
2
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
2
Overall Quick
Overall Rating
2
Pipe schematic from manhole 05 1843 to 05 1842
MH: 05 1843MH: 05 1842downstream0 ft. AMH - Upstream Manhole, Survey Begins - 5:25AM0 ft. MWL - Water Level, 10 %of cross sectional area0 ft. MWM - Water Mark, 20 %of cross sectional area28.1 ft. FC - Fracture Circumferential, from 07 to 09 o'clock, within 8 inches of joint: YES - SLIGHT117.9 ft. TF - Tap Factory Made, at 12 o'clock, -, within 8 inches of joint: YES, 6" - OPEN141.8 ft. TF - Tap Factory Made, at 12 o'clock, -, within 8 inches of joint: YES, 6" - OPEN195.8 ft. MGO - General Observation - 18" VCP195.8 ft. TFC - Tap Factory Made Capped, at 12 o'clock, -, within 8 inches of joint: YES, 6" - STUB252.6 ft. TF - Tap Factory Made, at 12 o'clock, -, within 8 inches of joint: YES, 6" - OPEN304.4 ft. TB - Tap Break-In, at 11 o'clock, -, within 8 inches of joint: YES, 6" - OPEN317.6 ft. TF - Tap Factory Made, at 12 o'clock, -, within 8 inches of joint: YES, 6" - ACTIVE410.4 ft. TF - Tap Factory Made, at 12 o'clock, -, within 8 inches of joint: YES, 6" - ACTIVE415.8 ft. MGO - General Observation - 18" VCP494.4 ft. AMH - Downstream Manhole, Survey Ends - 6:10AM

Observation photos (3)

  • General Observation - 18" VCP

    195.8 ft. - General Observation - 18" VCP

  • Tap Factory Made Capped, at 12 o'clock, -, within 8 inches of joint: YES, 6" - STUB

    195.8 ft. - Tap Factory Made Capped, at 12 o'clock, -, within 8 inches of joint: YES, 6" - STUB

  • General Observation - 18" VCP

    415.8 ft. - General Observation - 18" VCP

Observations (14)

DistanceCodeObservation
0AMH5:25AM
415.8MGO18" VCP
317.6TFACTIVE
304.4TBOPEN
0MWL
117.9TFOPEN
410.4TFACTIVE
494.4AMH6:10AM
195.8MGO18" VCP
0MWM
28.1FCSLIGHT
195.8TFCSTUB
141.8TFOPEN
252.6TFOPEN

Properties (4)

custom_field_three
1 LONG SLIGHT CIRCUM FRACTIRE
custom_field_two
4
customer
LACSD
datetime
2017-10-10T03:01:13-07:00