Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Oct 6, 2017, 10:53 AM
  • Section#2_05 1161_05 1160__1062017__G6842.mp4

Date
10/06/2017
W/O
#
Weather
Dry
Operator/Surveyor
MARTIN
Sewer ID
Z00437
PipeID
P06399
Time
3:53 AM
Certificate
U-1014-06022543
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
G6842
Sewer Name
05 EAST ROSECRANS AVENUE TRUNK, SECTION 2
City
GARDENA
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 05
Page No.
14
Purpose
Routine Assessment
Project
20171006MDM_EAST_ROSECRANS_AVENUE_TRUNK_SECTION_2
Material
Vitrified Clay Pipe
Shape
Circular
Height
15 in.
Upstream MH
05 1161
Downstream MH
05 1160
Dir. of Survey
Downstream
Length Surveyed
229.9 ft.
Total Length
229.9 ft.
Structural Index
2
Structural Quick
2700
Structural Rating
14
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
2
Overall Quick
Overall Rating
14
Pipe schematic from manhole 05 1161 to 05 1160
MH: 05 1161MH: 05 1160downstream0 ft. AMH - Upstream Manhole, Survey Begins - 3:55AM0 ft. MWM - Water Mark, 40 %of cross sectional area0 ft. MWL - Water Level, 10 %of cross sectional area8 ft. MGO - General Observation - 15" VCP14.4 ft. FC - Fracture Circumferential, from 11 to 02 o'clock, within 8 inches of joint: YES - SL19.8 ft. FC - Fracture Circumferential, from 10 to 12 o'clock, within 8 inches of joint: YES - HAIRLINE46.2 ft. FC - Fracture Circumferential, from 12 to 03 o'clock, within 8 inches of joint: YES - SL46.2 ft. FC - Fracture Circumferential, from 10 to 12 o'clock, within 8 inches of joint: YES - H70.3 ft. FC - Fracture Circumferential, from 03 to 04 o'clock, within 8 inches of joint: YES - H97.1 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: YES, 6" - ACTIVE124.1 ft. FC - Fracture Circumferential, from 01 to 03 o'clock, within 8 inches of joint: YES - H145.9 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 6" - STUB194.6 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 6" - STUB221 ft. FC - Fracture Circumferential, from 09 to 12 o'clock, within 8 inches of joint: YES - SL229.9 ft. MSA - Survey Abandoned - SLIPPY SUFARCE WILL COMPLETE REVERSE

Observation photos (1)

  • General Observation - 15" VCP

    8 ft. - General Observation - 15" VCP

Observations (15)

DistanceCodeObservation
19.8FCHAIRLINE
194.6TFCSTUB
221FCSL
0AMH3:55AM
97.1TFACTIVE
46.2FCSL
124.1FCH
229.9MSASLIPPY SUFARCE WILL COMPLETE REVERSE
0MWM
46.2FCH
14.4FCSL
70.3FCH
0MWL
8MGO15" VCP
145.9TFCSTUB

Properties (4)

custom_field_three
FEW SLIGHT FRACTURES
custom_field_two
4
customer
LACSD
datetime
2017-10-06T03:53:25-07:00