Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Aug 31, 2017, 05:20 AM
  • 05 1386_05 1385 _30082017_222049.mp4

Date
08/30/2017
W/O
652020
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00487
PipeID
P06606
Time
10:20 PM
Certificate
U-508-7069
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K4804
Sewer Name
05 MONETA TRUNK
City
GARDENA
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 05
Page No.
21
Purpose
Routine Assessment
Project
WO_652020_TV05074_AUG2017
Material
Vitrified Clay Pipe
Shape
Circular
Height
10 in.
Width
10 in.
Upstream MH
05 1386
Downstream MH
05 1385
Dir. of Survey
Downstream
Length Surveyed
48.7 ft.
Total Length
48.7 ft.
Structural Index
3
Structural Quick
3900
Structural Rating
27
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
27
Pipe schematic from manhole 05 1386 to 05 1385
MH: 05 1386MH: 05 1385downstream0 ft. AMH - Upstream Manhole, Survey Begins - 05 13860 ft. MWM - Water Mark, 20 %of cross sectional area0 ft. MGO - General Observation - CONNECTION AT MH 3 O'CLOCK0 ft. MGO - General Observation - CONNECTION AT MH 9 O'CLOCK0 ft. MWL - Water Level, 15 %of cross sectional area3 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start48.7 ft. AMH - Downstream Manhole, Survey Ends - 05 138548.7 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish48.7 ft. MGO - General Observation - CONNECTION AT MH 9 O'CLOCK48.7 ft. MGO - General Observation - CONNECTION AT MH 3 O'CLOCK CAPPED

Observation photos (1)

  • Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    3 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

Observations (10)

DistanceCodeObservation
48.7AMH05 1385
48.7CM
0AMH05 1386
0MWM
0MGOCONNECTION AT MH 3 O'CLOCK
48.7MGOCONNECTION AT MH 9 O'CLOCK
48.7MGOCONNECTION AT MH 3 O'CLOCK CAPPED
0MGOCONNECTION AT MH 9 O'CLOCK
3CM
0MWL

Properties (5)

additional_info
SC345913
custom_field_two
3
customer
LACSD
datetime
2017-08-30T22:20:31-07:00
sewer_category
Gravity