Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Aug 31, 2017, 11:00 AM
  • 05 1371_05 1326 _31082017_040120.mp4

Date
08/31/2017
W/O
652020
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00487
PipeID
P06590
Time
4:00 AM
Certificate
U-508-7069
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K4804
Sewer Name
05 MONETA TRUNK
City
GARDENA
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 05
Page No.
21
Purpose
Routine Assessment
Project
WO_652020_TV05074_AUG2017
Material
Vitrified Clay Pipe
Shape
Circular
Height
10 in.
Width
10 in.
Upstream MH
05 1371
Downstream MH
05 1326
Dir. of Survey
Downstream
Length Surveyed
327.9 ft.
Total Length
327.9 ft.
Structural Index
3
Structural Quick
3L00
Structural Rating
195
O&M Index
2
O&M Quick
2100
O&M Rating
2
Overall Index
3
Overall Quick
Overall Rating
197
Pipe schematic from manhole 05 1371 to 05 1326
MH: 05 1371MH: 05 1326downstream0 ft. AMH - Upstream Manhole, Survey Begins - 05 13710 ft. MGO - General Observation - CONNECTION AT MH 9 O'CLOCK0 ft. MWM - Water Mark, 25 %of cross sectional area0 ft. MGO - General Observation - CONNECTION AT MH 3 O'CLOCK0 ft. MWL - Water Level, 10 %of cross sectional area3 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start17.3 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"68.4 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"119.7 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"169.5 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 08 to 05 o'clock, , within 8 inches of joint: NO169.5 ft. TB - Tap Break-In, at 02 o'clock, -, within 8 inches of joint: NO, 6"170.8 ft. TFA - Tap Factory Made Active, at 10 o'clock, -, within 8 inches of joint: NO, 6"227.3 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"281.4 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"327.9 ft. AOC - Drop Connection, Survey Ends - 05 1326327.9 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish

Observation photos (3)

  • Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    3 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Deposits Attached Grease, 5 %of cross sectional area, from 08 to 05 o'clock,  , within 8 inches of joint: NO

    169.5 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 08 to 05 o'clock, , within 8 inches of joint: NO

  • Tap Break-In, at 02 o'clock, -, within 8 inches of joint: NO, 6"

    169.5 ft. - Tap Break-In, at 02 o'clock, -, within 8 inches of joint: NO, 6"

Observations (16)

DistanceCodeObservation
327.9AOC05 1326
281.4TFC
0AMH05 1371
327.9CM
169.5DAGS
169.5TB
68.4TFC
3CM
170.8TFA
0MGOCONNECTION AT MH 9 O'CLOCK
0MWM
17.3TFC
0MGOCONNECTION AT MH 3 O'CLOCK
119.7TFC
0MWL
227.3TFC

Properties (5)

additional_info
SC345913
custom_field_two
3
customer
LACSD
datetime
2017-08-31T04:00:48-07:00
sewer_category
Gravity