Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Aug 30, 2017, 09:12 AM
  • 05 1399_05 1398 _30082017_021257.mp4

Date
08/30/2017
W/O
652020
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00487
PipeID
P06620
Time
2:12 AM
Certificate
U-508-7069
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K4803
Sewer Name
05 MONETA TRUNK
City
GARDENA
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 05
Page No.
18
Purpose
Routine Assessment
Project
WO_652020_TV05074_AUG2017
Material
Vitrified Clay Pipe
Shape
Circular
Height
10 in.
Width
10 in.
Upstream MH
05 1398
Downstream MH
05 1399
Dir. of Survey
Upstream
Length Surveyed
327.5 ft.
Total Length
327.5 ft.
Structural Index
3
Structural Quick
3100
Structural Rating
3
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
3
Pipe schematic from manhole 05 1398 to 05 1399
MH: 05 1398MH: 05 1399upstream0 ft. AMH - Upstream Manhole, Survey Ends - 05 13990 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish23.5 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"74.9 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"136.4 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"185 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"236.3 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"292.7 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"322.6 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start327.5 ft. MWL - Water Level, 10 %of cross sectional area327.5 ft. MGO - General Observation - CONNECTION AT MH 9 O'CLOCK CAPPED327.5 ft. MWM - Water Mark, 20 %of cross sectional area327.5 ft. AMH - Downstream Manhole, Survey Begins - 05 1398327.5 ft. MGO - General Observation - CONNECTION AT MH 3 O'CLOCK

Observation photos (1)

  • Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    4.9 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

Observations (14)

DistanceCodeObservation
0MWL
142.5TFC
0MGOCONNECTION AT MH 9 O'CLOCK CAPPED
0MWM
191.1TFC
304TFC
0AMH05 1398
0MGOCONNECTION AT MH 3 O'CLOCK
34.8TFC
4.9CM
91.2TF
327.5AMH05 1399
252.6TFC
327.5CM

Properties (5)

additional_info
SC345912
custom_field_two
3
customer
LACSD
datetime
2017-08-30T02:12:32-07:00
sewer_category
Gravity