Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jul 3, 2017, 09:54 AM
  • 05 0959_05 0958 _03072017_032404.mp4

Date
07/03/2017
W/O
630086
Weather
Dry
Operator/Surveyor
JUAN B
Sewer ID
Z00481
PipeID
P06191
Time
2:54 AM
Certificate
U-715-07000770
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K4550
Sewer Name
05 MANCHESTER AVENUE PUMP TRUNK
City
LOS ANGELES
Loc. details
Railway
Location Code
L
Use of Sewer
Sanitary Sewer
District
District 05
Page No.
14
Purpose
Routine Assessment
Project
WO_630086_TV05069_JUN2017
Material
Vitrified Clay Pipe
Shape
Circular
Height
18 in.
Width
18 in.
Upstream MH
05 0959
Downstream MH
05 0958
Dir. of Survey
Downstream
Length Surveyed
295.5 ft.
Total Length
295.6 ft.
Structural Index
2
Structural Quick
3G2I
Structural Rating
224
O&M Index
2
O&M Quick
2K00
O&M Rating
118
Overall Index
2
Overall Quick
Overall Rating
342
Pipe schematic from manhole 05 0959 to 05 0958
MH: 05 0959MH: 05 0958downstream0 ft. MWM - Water Mark, 25 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 05 09590 ft. MWL - Water Level, 15 %of cross sectional area2.7 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start45.9 ft. TFC - Tap Factory Made Capped, at 03 o'clock, -, within 8 inches of joint: NO, 4"47.2 ft. CL - Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES53.3 ft. CL - Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES, Start90.4 ft. CM - Crack Multiple, from 11 to 01 o'clock, within 8 inches of joint: NO106.1 ft. CM - Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES, Start106.6 ft. TFC - Tap Factory Made Capped, at 03 o'clock, -, within 8 inches of joint: NO, 4"140.8 ft. FL - Fracture Longitudinal, at 01 o'clock, within 8 inches of joint: YES154.3 ft. TFC - Tap Factory Made Capped, at 03 o'clock, -, within 8 inches of joint: NO, 4"157.6 ft. FL - Fracture Longitudinal, at 02 o'clock, within 8 inches of joint: YES205.5 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 4"208.7 ft. FS - Fracture Spiral, from 02 to 03 o'clock, within 8 inches of joint: YES253.3 ft. TFC - Tap Factory Made Capped, at 03 o'clock, -, within 8 inches of joint: NO, 4"295.6 ft. MGO - General Observation - CONNECTION AT 3 OC295.6 ft. CL - Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES, Finish295.6 ft. CM - Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES, Finish295.6 ft. AMH - Downstream Manhole, Survey Ends - 05 0958295.6 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish

Observation photos (8)

  • Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock,  , within 8 inches of joint: YES, Start

    2.7 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start

  • Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES

    47.2 ft. - Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES

  • Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES, Start

    53.3 ft. - Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES, Start

  • Crack Multiple, from 11 to 01 o'clock, within 8 inches of joint: NO

    90.4 ft. - Crack Multiple, from 11 to 01 o'clock, within 8 inches of joint: NO

  • Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

    106.1 ft. - Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

  • Fracture Longitudinal, at 01 o'clock, within 8 inches of joint: YES

    140.8 ft. - Fracture Longitudinal, at 01 o'clock, within 8 inches of joint: YES

  • Fracture Longitudinal, at 02 o'clock, within 8 inches of joint: YES

    157.6 ft. - Fracture Longitudinal, at 02 o'clock, within 8 inches of joint: YES

  • Fracture Spiral, from 02 to 03 o'clock, within 8 inches of joint: YES

    208.7 ft. - Fracture Spiral, from 02 to 03 o'clock, within 8 inches of joint: YES

Observations (21)

DistanceCodeObservation
0MWM
106.6TFC
154.3TFC
0AMH05 0959
205.5TFC
253.3TFC
2.7DAGS
45.9TFC
295.6MGOCONNECTION AT 3 OC
208.7FS
106.1CM
47.2CL
295.6CL
140.8FL
53.3CL
295.6CM
90.4CM
295.6AMH05 0958
0MWL
295.6DAGS
157.6FL

Properties (5)

additional_info
SC345381
custom_field_two
2
customer
LACSD
datetime
2017-07-03T02:54:32-07:00
sewer_category
Gravity