- Date
- 10/03/2017
- W/O
- 0596837
- Weather
- Dry
- Operator/Surveyor
- SANTIAGO OBREGON
- Sewer ID
- Z00819
- PipeID
- P17392
- Time
- 11:28 AM
- Certificate
- U-1014-06022541
- System Owner
- LACSD
- Date Cleaned
- —
- Pre-Cleaning
- Not Known
- Media Label
- G7527
- Sewer Name
- 22 LORAINE TRUNK
- City
- GLENDORA
- Loc. details
- Light Highway
- Location Code
- C
- Use of Sewer
- Sanitary Sewer
- District
- District 22
- Page No.
- 14
- Purpose
- Routine Assessment
- Project
- 20171003SHO_LORAINE_TRUNK
- Material
- Vitrified Clay Pipe
- Shape
- Circular
- Height
- 12 in.
- Upstream MH
- 22 1023
- Downstream MH
- 22 1022
- Dir. of Survey
- Downstream
- Length Surveyed
- 118 ft.
- Total Length
- 118 ft.
- Structural Index
- 1
- Structural Quick
- 2112
- Structural Rating
- 4
- O&M Index
- 0
- O&M Quick
- 0000
- O&M Rating
- 0
- Overall Index
- 1
- Overall Quick
- —
- Overall Rating
- 4
Pipe schematic from manhole 22 1023 to 22 1022 Observation photos (3)

34 ft. - Joint Offset Medium

36.8 ft. - Joint Offset Medium

48 ft. - Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES - JOINT TO JOINT