Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Oct 3, 2017, 07:51 AM
  • Section#6_G 0314_G 0313__1032017__G6835.mp4

Date
10/03/2017
W/O
0646225
Weather
Dry
Operator/Surveyor
MARTIN
Sewer ID
Z00228
PipeID
P01750
Time
12:51 AM
Certificate
U-1014-06022543
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
G6835
Sewer Name
G JOIINT OUTFALL G- UNIT 9 TRUNK
City
SOUTH GATE
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 01
Page No.
11
Purpose
Capital Improvement Program Assesment
Project
20171002MDM_JOINT_OUTFALL_G_UNIT_9_TRUNK
Material
RCP-CTL
Shape
Circular
Height
33 in.
Upstream MH
G 0314
Downstream MH
G 0313
Dir. of Survey
Downstream
Length Surveyed
300.6 ft.
Total Length
300.6 ft.
Structural Index
4
Structural Quick
5D4K
Structural Rating
370
O&M Index
4
O&M Quick
5B3E
O&M Rating
159
Overall Index
4
Overall Quick
Overall Rating
529
Pipe schematic from manhole G 0314 to G 0313
MH: G 0314MH: G 0313downstream0 ft. MWL - Water Level, 30 %of cross sectional area0 ft. MWM - Water Mark, 40 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 2:30AM2 ft. DSZ - Deposits Settled Other, 35 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Start - FALLEN TILES & DEBRIE2 ft. MGO - General Observation - 70% MISSING TILES START 9:00 TO 3:002 ft. SAM - Surface Aggregate Missing, from 09 to 03 o'clock, within 8 inches of joint: YES, Start - SEVERE AGG AREAS OF MISSING TILES2.2 ft. SRC - Surface Reinforcement Corroded, from 10 to 02 o'clock, within 8 inches of joint: NO - CIRCUM REBAR4.2 ft. SRV - Surface Reinforcement Visible, from 01 to 03 o'clock, within 8 inches of joint: NO - CIRCUM REBAR14.3 ft. SRV - Surface Reinforcement Visible, from 02 to 03 o'clock, within 8 inches of joint: NO - CIRCUM REBASR21.9 ft. SRV - Surface Reinforcement Visible, from 10 to 11 o'clock, within 8 inches of joint: NO - CIRCUM REBAR26.3 ft. SRC - Surface Reinforcement Corroded, from 10 to 12 o'clock, within 8 inches of joint: YES - CIRCUM REBAR36.9 ft. SRV - Surface Reinforcement Visible, at 12 o'clock, within 8 inches of joint: NO - LONG REBAR40.3 ft. SRV - Surface Reinforcement Visible, from 12 to 02 o'clock, within 8 inches of joint: NO - LONG CIRCUM REBAR41.9 ft. SRV - Surface Reinforcement Visible, from 10 to 02 o'clock, within 8 inches of joint: YES - CIRCUM REBAR48 ft. SRV - Surface Reinforcement Visible, from 10 to 12 o'clock, within 8 inches of joint: YES - LONG CIRCUM REBAR63.8 ft. SRV - Surface Reinforcement Visible, from 10 to 02 o'clock, within 8 inches of joint: YES - CIRCUM REBAR71.1 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 04 o'clock, , within 8 inches of joint: NO72.7 ft. MGO - General Observation - 30% MISSING TILES START 8:00 TO 4:0072.7 ft. DSZ - Deposits Settled Other, 35 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Finish - FALLEN TILES72.7 ft. MWM - Water Mark, 30 %of cross sectional area72.7 ft. MWL - Water Level, 20 %of cross sectional area87.6 ft. SRV - Surface Reinforcement Visible, from 01 to 02 o'clock, within 8 inches of joint: YES - CIRCUM REBAR103 ft. MGO - General Observation - 90% MISSING TILES105.3 ft. SRV - Surface Reinforcement Visible, from 10 to 12 o'clock, within 8 inches of joint: YES - CIRCUM REBAR111.6 ft. SRV - Surface Reinforcement Visible, from 01 to 02 o'clock, within 8 inches of joint: YES - CIRCUM REBAR123.3 ft. MGO - General Observation - 95% MISSING TILES START127.1 ft. SRV - Surface Reinforcement Visible, at 01 o'clock, within 8 inches of joint: NO - CIRCUM REBAR129.2 ft. SRC - Surface Reinforcement Corroded, from 10 to 02 o'clock, within 8 inches of joint: YES, Start - LONG CIRCUM REBAR139.9 ft. SRC - Surface Reinforcement Corroded, from 10 to 02 o'clock, within 8 inches of joint: YES, Finish - LONG CIRCUM REBAR149.6 ft. SRV - Surface Reinforcement Visible, from 10 to 12 o'clock, within 8 inches of joint: NO - CIRCUM REBAR157.8 ft. DSZ - Deposits Settled Other, 20 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start - TILES & DEBRIE160.6 ft. MGO - General Observation - 30% MISSING TILES ATART175.8 ft. MGO - General Observation - 90% MISSING TILES176.7 ft. SRC - Surface Reinforcement Corroded, from 10 to 02 o'clock, within 8 inches of joint: YES, Start - LONG CIRCUM REBAR180.6 ft. SRC - Surface Reinforcement Corroded, from 10 to 02 o'clock, within 8 inches of joint: YES, Finish - LONG CIRCUM REBAR187 ft. MGO - General Observation - DEBRIE ON CABLE AFFECTED FOOTAGE COUNTER197 ft. SRV - Surface Reinforcement Visible, from 10 to 03 o'clock, within 8 inches of joint: YES, - LONG CIRCUM REBAR210 ft. MGO - General Observation - 50% MISSING220 ft. MGO - General Observation - 90% MISSING230 ft. SRV - Surface Reinforcement Visible, at 12 o'clock, within 8 inches of joint: NO - LONG REBAR240 ft. MGO - General Observation - 50% MISSING TILES250 ft. SRC - Surface Reinforcement Corroded, from 10 to 02 o'clock, within 8 inches of joint: YES, - LONG CIRCUM REBAR260 ft. MGO - General Observation - 90% MISSING265 ft. MGO - General Observation - 40% MISSING TILES270 ft. MGO - General Observation - 100% MISSING TILES270 ft. SRV - Surface Reinforcement Visible, from 10 to 11 o'clock, within 8 inches of joint: NO - CIRCUM275 ft. SRC - Surface Reinforcement Corroded, from 10 to 02 o'clock, within 8 inches of joint: YES - LONG CIRCUM REBAR280 ft. MGO - General Observation - 100% MISSING TILES282.6 ft. SRC - Surface Reinforcement Corroded, from 10 to 02 o'clock, within 8 inches of joint: YES, Start - CIRCUM287.2 ft. SRC - Surface Reinforcement Corroded, from 10 to 02 o'clock, within 8 inches of joint: YES, Finish - CIRCUM REBAR295.5 ft. MGO - General Observation - DEBRIE ON CABLE300.3 ft. DSZ - Deposits Settled Other, 20 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish - FALLEN TILES300.3 ft. SAM - Surface Aggregate Missing, from 09 to 03 o'clock, within 8 inches of joint: YES, Finish - SEVERE AGG AREAS OF MISSING TILES300.6 ft. AMH - Downstream Manhole, Survey Ends - 3:35AM

Observation photos (39)

  • Deposits Settled Other,  35 %of cross sectional area, from 03 to 09 o'clock,  , within 8 inches of joint: YES, Start - FALLEN TILES & DEBRIE

    2 ft. - Deposits Settled Other, 35 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Start - FALLEN TILES & DEBRIE

  • General Observation - 70% MISSING TILES START 9:00 TO 3:00

    2 ft. - General Observation - 70% MISSING TILES START 9:00 TO 3:00

  • Surface Aggregate Missing, from 09 to 03 o'clock, within 8 inches of joint: YES, Start - SEVERE AGG AREAS OF MISSING TILES

    2 ft. - Surface Aggregate Missing, from 09 to 03 o'clock, within 8 inches of joint: YES, Start - SEVERE AGG AREAS OF MISSING TILES

  • Surface Reinforcement Corroded, from 10 to 02 o'clock, within 8 inches of joint: NO - CIRCUM REBAR

    2.2 ft. - Surface Reinforcement Corroded, from 10 to 02 o'clock, within 8 inches of joint: NO - CIRCUM REBAR

  • Surface Reinforcement Visible, from 01 to 03 o'clock, within 8 inches of joint: NO - CIRCUM REBAR

    4.2 ft. - Surface Reinforcement Visible, from 01 to 03 o'clock, within 8 inches of joint: NO - CIRCUM REBAR

  • Surface Reinforcement Visible, from 02 to 03 o'clock, within 8 inches of joint: NO - CIRCUM REBASR

    14.3 ft. - Surface Reinforcement Visible, from 02 to 03 o'clock, within 8 inches of joint: NO - CIRCUM REBASR

  • Surface Reinforcement Visible, from 10 to 11 o'clock, within 8 inches of joint: NO - CIRCUM REBAR

    21.9 ft. - Surface Reinforcement Visible, from 10 to 11 o'clock, within 8 inches of joint: NO - CIRCUM REBAR

  • Surface Reinforcement Corroded, from 10 to 12 o'clock, within 8 inches of joint: YES - CIRCUM REBAR

    26.3 ft. - Surface Reinforcement Corroded, from 10 to 12 o'clock, within 8 inches of joint: YES - CIRCUM REBAR

  • Surface Reinforcement Visible, at 12 o'clock, within 8 inches of joint: NO - LONG REBAR

    36.9 ft. - Surface Reinforcement Visible, at 12 o'clock, within 8 inches of joint: NO - LONG REBAR

  • Surface Reinforcement Visible, from 12 to 02 o'clock, within 8 inches of joint: NO - LONG CIRCUM REBAR

    40.3 ft. - Surface Reinforcement Visible, from 12 to 02 o'clock, within 8 inches of joint: NO - LONG CIRCUM REBAR

  • Surface Reinforcement Visible, from 10 to 02 o'clock, within 8 inches of joint: YES - CIRCUM REBAR

    41.9 ft. - Surface Reinforcement Visible, from 10 to 02 o'clock, within 8 inches of joint: YES - CIRCUM REBAR

  • Surface Reinforcement Visible, from 10 to 12 o'clock, within 8 inches of joint: YES - LONG CIRCUM REBAR

    48 ft. - Surface Reinforcement Visible, from 10 to 12 o'clock, within 8 inches of joint: YES - LONG CIRCUM REBAR

  • Surface Reinforcement Visible, from 10 to 02 o'clock, within 8 inches of joint: YES - CIRCUM REBAR

    63.8 ft. - Surface Reinforcement Visible, from 10 to 02 o'clock, within 8 inches of joint: YES - CIRCUM REBAR

  • General Observation - 30% MISSING TILES START 8:00 TO 4:00

    72.7 ft. - General Observation - 30% MISSING TILES START 8:00 TO 4:00

  • Surface Reinforcement Visible, from 01 to 02 o'clock, within 8 inches of joint: YES - CIRCUM REBAR

    87.6 ft. - Surface Reinforcement Visible, from 01 to 02 o'clock, within 8 inches of joint: YES - CIRCUM REBAR

  • General Observation - 90% MISSING TILES

    103 ft. - General Observation - 90% MISSING TILES

  • Surface Reinforcement Visible, from 01 to 02 o'clock, within 8 inches of joint: YES - CIRCUM REBAR

    111.6 ft. - Surface Reinforcement Visible, from 01 to 02 o'clock, within 8 inches of joint: YES - CIRCUM REBAR

  • General Observation - 95% MISSING TILES START

    123.3 ft. - General Observation - 95% MISSING TILES START

  • Surface Reinforcement Visible, at 01 o'clock, within 8 inches of joint: NO - CIRCUM REBAR

    127.1 ft. - Surface Reinforcement Visible, at 01 o'clock, within 8 inches of joint: NO - CIRCUM REBAR

  • Surface Reinforcement Corroded, from 10 to 02 o'clock, within 8 inches of joint: YES, Start - LONG CIRCUM REBAR

    129.2 ft. - Surface Reinforcement Corroded, from 10 to 02 o'clock, within 8 inches of joint: YES, Start - LONG CIRCUM REBAR

  • Surface Reinforcement Visible, from 10 to 12 o'clock, within 8 inches of joint: NO - CIRCUM REBAR

    149.6 ft. - Surface Reinforcement Visible, from 10 to 12 o'clock, within 8 inches of joint: NO - CIRCUM REBAR

  • Deposits Settled Other,  20 %of cross sectional area, from 04 to 08 o'clock,  , within 8 inches of joint: YES, Start - TILES & DEBRIE

    157.8 ft. - Deposits Settled Other, 20 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start - TILES & DEBRIE

  • General Observation - 30% MISSING TILES ATART

    160.6 ft. - General Observation - 30% MISSING TILES ATART

  • General Observation - 90% MISSING TILES

    175.8 ft. - General Observation - 90% MISSING TILES

  • Surface Reinforcement Corroded, from 10 to 02 o'clock, within 8 inches of joint: YES, Start - LONG CIRCUM REBAR

    176.7 ft. - Surface Reinforcement Corroded, from 10 to 02 o'clock, within 8 inches of joint: YES, Start - LONG CIRCUM REBAR

  • Surface Reinforcement Corroded, from 10 to 02 o'clock, within 8 inches of joint: YES, Finish - LONG CIRCUM REBAR

    180.6 ft. - Surface Reinforcement Corroded, from 10 to 02 o'clock, within 8 inches of joint: YES, Finish - LONG CIRCUM REBAR

  • Surface Reinforcement Visible, from 10 to 03 o'clock, within 8 inches of joint: YES,  - LONG CIRCUM REBAR

    197 ft. - Surface Reinforcement Visible, from 10 to 03 o'clock, within 8 inches of joint: YES, - LONG CIRCUM REBAR

  • General Observation - 50% MISSING

    210 ft. - General Observation - 50% MISSING

  • General Observation - 90% MISSING

    220 ft. - General Observation - 90% MISSING

  • Surface Reinforcement Visible, at 12 o'clock, within 8 inches of joint: NO - LONG REBAR

    230 ft. - Surface Reinforcement Visible, at 12 o'clock, within 8 inches of joint: NO - LONG REBAR

  • General Observation - 50% MISSING TILES

    240 ft. - General Observation - 50% MISSING TILES

  • Surface Reinforcement Corroded, from 10 to 02 o'clock, within 8 inches of joint: YES,  - LONG CIRCUM REBAR

    250 ft. - Surface Reinforcement Corroded, from 10 to 02 o'clock, within 8 inches of joint: YES, - LONG CIRCUM REBAR

  • General Observation - 90% MISSING

    260 ft. - General Observation - 90% MISSING

  • General Observation - 40% MISSING TILES

    265 ft. - General Observation - 40% MISSING TILES

  • General Observation - 100% MISSING TILES

    270 ft. - General Observation - 100% MISSING TILES

  • Surface Reinforcement Visible, from 10 to 11 o'clock, within 8 inches of joint: NO - CIRCUM

    270 ft. - Surface Reinforcement Visible, from 10 to 11 o'clock, within 8 inches of joint: NO - CIRCUM

  • General Observation - 100% MISSING TILES

    280 ft. - General Observation - 100% MISSING TILES

  • Surface Reinforcement Corroded, from 10 to 02 o'clock, within 8 inches of joint: YES, Start - CIRCUM

    282.6 ft. - Surface Reinforcement Corroded, from 10 to 02 o'clock, within 8 inches of joint: YES, Start - CIRCUM

  • General Observation - DEBRIE ON CABLE

    295.5 ft. - General Observation - DEBRIE ON CABLE

Observations (54)

DistanceCodeObservation
21.9SRVCIRCUM REBAR
300.3DSZFALLEN TILES
127.1SRVCIRCUM REBAR
2DSZFALLEN TILES & DEBRIE
40.3SRVLONG CIRCUM REBAR
260MGO90% MISSING
103MGO90% MISSING TILES
72.7MGO30% MISSING TILES START 8:00 TO 4:00
129.2SRCLONG CIRCUM REBAR
0MWL
287.2SRCCIRCUM REBAR
2.2SRCCIRCUM REBAR
0MWM
275SRCLONG CIRCUM REBAR
270MGO100% MISSING TILES
72.7DSZFALLEN TILES
270SRVCIRCUM
63.8SRVCIRCUM REBAR
2MGO70% MISSING TILES START 9:00 TO 3:00
87.6SRVCIRCUM REBAR
197SRVLONG CIRCUM REBAR
41.9SRVCIRCUM REBAR
123.3MGO95% MISSING TILES START
300.6AMH3:35AM
72.7MWM
4.2SRVCIRCUM REBAR
72.7MWL
220MGO90% MISSING
14.3SRVCIRCUM REBASR
175.8MGO90% MISSING TILES
36.9SRVLONG REBAR
105.3SRVCIRCUM REBAR
295.5MGODEBRIE ON CABLE
280MGO100% MISSING TILES
111.6SRVCIRCUM REBAR
157.8DSZTILES & DEBRIE
250SRCLONG CIRCUM REBAR
2SAMSEVERE AGG AREAS OF MISSING TILES
230SRVLONG REBAR
176.7SRCLONG CIRCUM REBAR
0AMH2:30AM
48SRVLONG CIRCUM REBAR
149.6SRVCIRCUM REBAR
187MGODEBRIE ON CABLE AFFECTED FOOTAGE COUNTER
71.1DAGS
240MGO50% MISSING TILES
160.6MGO30% MISSING TILES ATART
210MGO50% MISSING
180.6SRCLONG CIRCUM REBAR
282.6SRCCIRCUM
300.3SAMSEVERE AGG AREAS OF MISSING TILES
139.9SRCLONG CIRCUM REBAR
26.3SRCCIRCUM REBAR
265MGO40% MISSING TILES

Properties (4)

custom_field_three
LONG & CIRCUM REBAR
custom_field_two
1
customer
LACSD
datetime
2017-10-03T00:51:40-07:00