Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Aug 24, 2017, 06:27 AM
  • 02 2175_02 2174 _23082017_232749.mp4

Date
08/23/2017
W/O
652201
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00261
PipeID
P04449
Time
11:27 PM
Certificate
U-508-7069
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K4792
Sewer Name
02 FOSTER ROAD TRUNK
City
DOWNEY
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 02
Page No.
33
Purpose
Routine Assessment
Project
WO_652201_TV02290_AUG2017
Material
Vitrified Clay Pipe
Shape
Circular
Height
24 in.
Width
24 in.
Upstream MH
02 2175
Downstream MH
02 2174
Dir. of Survey
Downstream
Length Surveyed
247.6 ft.
Total Length
247.6 ft.
Structural Index
2
Structural Quick
2I00
Structural Rating
96
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
2
Overall Quick
Overall Rating
96
Pipe schematic from manhole 02 2175 to 02 2174
MH: 02 2175MH: 02 2174downstream0 ft. MGO - General Observation - SERVICE CONNECTION AT 3 O' CLOCK AT MH0 ft. AMH - Upstream Manhole, Survey Begins - 02 21750 ft. MWM - Water Mark, 25 %of cross sectional area0 ft. MWL - Water Level, 20 %of cross sectional area2 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start244 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish247.6 ft. MGO - General Observation - SERVICE CONNECTION AT 3 O' CLOCK AT MH247.6 ft. AMH - Downstream Manhole, Survey Ends - 02 2174

Observations (8)

DistanceCodeObservation
0MGOSERVICE CONNECTION AT 3 O' CLOCK AT MH
247.6MGOSERVICE CONNECTION AT 3 O' CLOCK AT MH
0AMH02 2175
2SSS
0MWM
244SSS
0MWL
247.6AMH02 2174

Properties (6)

additional_info
SC345901
custom_field_two
3
customer
LACSD
datetime
2017-08-23T23:27:33-07:00
sewer_category
Gravity
year_laid
31114