Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Aug 25, 2017, 09:29 AM
  • 02 2165_02 2164 _25082017_023020.mp4

Date
08/25/2017
W/O
652201
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00261
PipeID
P04439
Time
2:29 AM
Certificate
U-508-7069
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K4797
Sewer Name
02 FOSTER ROAD TRUNK
City
BELLFLOWER
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 02
Page No.
33
Purpose
Routine Assessment
Project
WO_652201_TV02290_AUG2017
Material
Vitrified Clay Pipe
Shape
Circular
Height
27 in.
Width
27 in.
Upstream MH
02 2165
Downstream MH
02 2164
Dir. of Survey
Downstream
Length Surveyed
480.2 ft.
Total Length
480.2 ft.
Structural Index
2
Structural Quick
2R00
Structural Rating
190
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
2
Overall Quick
Overall Rating
190
Pipe schematic from manhole 02 2165 to 02 2164
MH: 02 2165MH: 02 2164downstream0 ft. AMH - Upstream Manhole, Survey Begins - 02 21650 ft. MWL - Water Level, 10 %of cross sectional area0 ft. MWM - Water Mark, 25 %of cross sectional area2 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start475 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish480.2 ft. AMH - Downstream Manhole, Survey Ends - 02 2164

Observations (6)

DistanceCodeObservation
2SSS
0AMH02 2165
480.2AMH02 2164
0MWL
475SSS
0MWM

Properties (6)

additional_info
SC345906
custom_field_two
3
customer
LACSD
datetime
2017-08-25T02:29:52-07:00
sewer_category
Gravity
year_laid
31114