Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jul 17, 2017, 10:16 AM
  • 02 0885_02 0884 _17072017_031635.mp4

Date
07/17/2017
W/O
646417
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00249
PipeID
P03453
Time
3:16 AM
Certificate
U-508-7069
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K4652
Sewer Name
02 DOWNEY TRUNK
City
DOWNEY
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 02
Page No.
27
Purpose
Routine Assessment
Project
WO_646417_TV02050_JUL2017
Material
NRCP
Shape
Circular
Height
15 in.
Width
15 in.
Upstream MH
02 0885
Downstream MH
02 0884
Dir. of Survey
Downstream
Length Surveyed
292.3 ft.
Total Length
292.3 ft.
Structural Index
3
Structural Quick
3K00
Structural Rating
174
O&M Index
2
O&M Quick
2100
O&M Rating
2
Overall Index
3
Overall Quick
Overall Rating
176
Pipe schematic from manhole 02 0885 to 02 0884
MH: 02 0885MH: 02 0884downstream0 ft. MWL - Water Level, 10 %of cross sectional area0 ft. MWM - Water Mark, 25 %of cross sectional area0 ft. MGO - General Observation - CONNECTION AT MH 6 O'CLOCK0 ft. AMH - Upstream Manhole, Survey Begins - 02 08852.1 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start35.7 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"107.8 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"236.1 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"236.1 ft. TFD - Tap Factory Made Defective, at 10 o'clock, -, within 8 inches of joint: NO, 6" - BROKEN/LARGE VOID292.3 ft. AMH - Downstream Manhole, Survey Ends - 02 0884292.3 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish

Observation photos (2)

  • Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2.1 ft. - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Tap Factory Made Defective, at 10 o'clock, -, within 8 inches of joint: NO, 6" - BROKEN/LARGE VOID

    236.1 ft. - Tap Factory Made Defective, at 10 o'clock, -, within 8 inches of joint: NO, 6" - BROKEN/LARGE VOID

Observations (11)

DistanceCodeObservation
2.1SAV
0MWL
0MWM
292.3AMH02 0884
107.8TF
236.1TFC
292.3SAV
0MGOCONNECTION AT MH 6 O'CLOCK
236.1TFDBROKEN/LARGE VOID
35.7TFC
0AMH02 0885

Properties (5)

additional_info
SC345512
custom_field_two
3
customer
LACSD
datetime
2017-07-17T03:16:28-07:00
sewer_category
Gravity