Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jul 19, 2017, 09:01 AM
  • 02 0877_02 0876_19072017_020114.mp4

Date
07/19/2017
W/O
646417
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00249
PipeID
P03444
Time
2:01 AM
Certificate
U-508-7069
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K4654
Sewer Name
02 DOWNEY TRUNK
City
DOWNEY
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 02
Page No.
27
Purpose
Routine Assessment
Project
WO_646417_TV02050_JUL2017
Material
NRCP
Shape
Circular
Height
15 in.
Width
15 in.
Upstream MH
02 0877
Downstream MH
02 0876
Dir. of Survey
Downstream
Length Surveyed
354.1 ft.
Total Length
354.2 ft.
Structural Index
3
Structural Quick
3M00
Structural Rating
210
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
210
Pipe schematic from manhole 02 0877 to 02 0876
MH: 02 0877MH: 02 0876downstream0 ft. MWM - Water Mark, 25 %of cross sectional area0 ft. MWL - Water Level, 10 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 02 08772.1 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start5.3 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"42.9 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"248.1 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"294.9 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"343.7 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"354.2 ft. AMH - Downstream Manhole, Survey Ends - 02 0876354.2 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish

Observation photos (1)

  • Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2.1 ft. - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

Observations (11)

DistanceCodeObservation
42.9TFC
354.2AMH02 0876
343.7TFC
5.3TFC
248.1TFC
0MWM
0MWL
0AMH02 0877
2.1SAV
354.2SAV
294.9TFC

Properties (5)

additional_info
SC345514
custom_field_two
3
customer
LACSD
datetime
2017-07-19T02:01:05-07:00
sewer_category
Gravity