Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jun 9, 2017, 07:05 AM
  • 05 2566_05 2565 _09062017_011304.mp4

Date
06/09/2017
W/O
641198
Weather
Dry
Operator/Surveyor
M.MARTINEZ
Sewer ID
Z01131
PipeID
P25267
Time
12:05 AM
Certificate
U-115-06022794
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K3967-SC342120
Sewer Name
05 COLDEN AVENUE RELIEF TRUNK
City
LOS ANGELES
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 01
Page No.
09
Purpose
Routine Assessment
Project
WO_641198_TV05127_JUN2017
Sewer Type
Siphon
Material
Vitrified Clay Pipe
Shape
Circular
Height
18 in.
Width
18 in.
Upstream MH
05 2566
Downstream MH
05 2565
Dir. of Survey
Downstream
Length Surveyed
2 ft.
Total Length
2 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
4
O&M Quick
5121
O&M Rating
7
Overall Index
4
Overall Quick
Overall Rating
7
Pipe schematic from manhole 05 2566 to 05 2565
MH: 05 2566MH: 05 2565downstream0 ft. MWM - Water Mark, 80 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 05 25660 ft. MWL - Water Level, 15 %of cross sectional area2 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES2 ft. MSA - Survey Abandoned - DOWNLEG SIPHON FROM UPSTREM MH

Observation photos (2)

  • Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock,  , within 8 inches of joint: YES

    2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES

  • Survey Abandoned - DOWNLEG SIPHON FROM UPSTREM MH

    2 ft. - Survey Abandoned - DOWNLEG SIPHON FROM UPSTREM MH

Observations (5)

DistanceCodeObservation
2DAGS
0MWM
0AMH05 2566
2MSADOWNLEG SIPHON FROM UPSTREM MH
0MWL

Properties (4)

custom_field_two
3
customer
LACSD
datetime
2017-06-09T00:05:22-07:00
year_laid
38590