Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Aug 14, 2017, 08:36 AM
  • 28 0053_28 0052 _14082017_013653.mp4

Date
08/14/2017
W/O
646221
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00912
PipeID
P21808
Time
1:36 AM
Certificate
U-508-7069
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K4779
Sewer Name
28 FOOTHILL BOULEVARD MAIN TRUNK
City
LA CANADA FLINTRIDGE
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 28
Page No.
04
Purpose
Routine Assessment
Project
WO_646221_TV28001_JUL2017
Material
Vitrified Clay Pipe
Shape
Circular
Height
18 in.
Width
18 in.
Upstream MH
28 0052
Downstream MH
28 0053
Dir. of Survey
Upstream
Length Surveyed
145.1 ft.
Total Length
145.1 ft.
Structural Index
1
Structural Quick
1100
Structural Rating
1
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
1
Overall Quick
Overall Rating
1
Pipe schematic from manhole 28 0052 to 28 0053
MH: 28 0052MH: 28 0053upstream0 ft. AMH - Upstream Manhole, Survey Ends - 28 00537 ft. CC - Crack Circumferential, from 10 to 02 o'clock, within 8 inches of joint: YES140.4 ft. TFA - Tap Factory Made Active, at 12 o'clock, -, within 8 inches of joint: NO, 6"145.1 ft. MWL - Water Level, 10 %of cross sectional area145.1 ft. AMH - Downstream Manhole, Survey Begins - 28 0052145.1 ft. MWM - Water Mark, 20 %of cross sectional area

Observation photos (1)

  • Crack Circumferential, from 10 to 02 o'clock, within 8 inches of joint: YES

    138.1 ft. - Crack Circumferential, from 10 to 02 o'clock, within 8 inches of joint: YES

Observations (6)

DistanceCodeObservation
138.1CC
0MWL
0AMH28 0052
145.1AMH28 0053
4.7TFA
0MWM

Properties (6)

additional_info
SC345539
custom_field_two
4
customer
LACSD
datetime
2017-08-14T01:36:43-07:00
sewer_category
Gravity
year_laid
35489