B 1137_B 1136_05072017_235057.mp4
26.7 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES
32.2 ft. - Crack Longitudinal, at 02 o'clock, within 8 inches of joint: YES
42.8 ft. - Crack Longitudinal, at 09 o'clock, within 8 inches of joint: YES
47.4 ft. - Crack Longitudinal, at 02 o'clock, within 8 inches of joint: YES
60.1 ft. - General Observation - PIPE MISSING
70.3 ft. - Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES, Start
86.1 ft. - Tap Break-In, at 09 o'clock, -, within 8 inches of joint: NO, 6"
238.3 ft. - Tap Break-In, at 10 o'clock, -, within 8 inches of joint: NO, 6"
| Distance | Code | Observation |
|---|---|---|
| 70.3 | CM | — |
| 42.8 | CL | — |
| 86.1 | TB | — |
| 155.9 | TF | — |
| 57.5 | TF | — |
| 199.3 | TF | — |
| 26.7 | CM | — |
| 0 | MWM | — |
| 277.3 | CM | — |
| 47.4 | CL | — |
| 239.2 | TF | — |
| 238.3 | TB | — |
| 277.3 | AMH | B 1136 |
| 250.4 | TFC | — |
| 148.5 | TF | — |
| 89.6 | TFC | — |
| 270.4 | TF | — |
| 60.1 | MGO | PIPE MISSING |
| 57.5 | RML | — |
| 104.4 | TF | — |
| 0 | AMH | B 1137 |
| 22.3 | TF | — |
| 32.2 | CL | — |
| 38 | TF | — |
| 171.2 | TF | — |
| 0 | MWL | — |