Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jul 26, 2017, 07:12 PM
  • 03 0079_03 0078_15082017_150903.mp4

Date
07/26/2017
W/O
1590881
Weather
Dry
Operator/Surveyor
M.MARTINEZ
Sewer ID
Z00366
PipeID
P05101
Time
12:12 PM
Certificate
U-115-06022794
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K3993
Sewer Name
03 LOS COYOTES DIAGONAL TRUNK
City
CERRITOS
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 03
Page No.
05
Purpose
Routine Assessment
Project
WO_646534_TV03011_JUL2017
Material
Vitrified Clay Pipe
Shape
Circular
Height
12 in.
Width
12 in.
Upstream MH
03 0079
Downstream MH
03 0078
Dir. of Survey
Downstream
Length Surveyed
217.4 ft.
Total Length
217.4 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
2
O&M Quick
2G00
O&M Rating
84
Overall Index
2
Overall Quick
Overall Rating
84
Pipe schematic from manhole 03 0079 to 03 0078
MH: 03 0079MH: 03 0078downstream0 ft. AMH - Upstream Manhole, Survey Begins - 03 00790 ft. MWM - Water Mark, 40 %of cross sectional area0 ft. MWL - Water Level, 10 %of cross sectional area2 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start2 ft. MGO - General Observation - GROUT HANGING IN PIPE29.1 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: YES, 6"33.1 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: YES, 6", 6"71 ft. TB - Tap Break-In, at 10 o'clock, -, within 8 inches of joint: YES, 6"99.1 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: YES, 6"173.1 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 6"214.1 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish217 ft. MGO - General Observation - CONNECTION AT 9 O'CLOCK217.4 ft. AMH - Downstream Manhole, Survey Ends - 03 0078

Observation photos (2)

  • Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock,  , within 8 inches of joint: YES, Start

    2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start

  • General Observation - GROUT HANGING IN PIPE

    2 ft. - General Observation - GROUT HANGING IN PIPE

Observations (13)

DistanceCodeObservation
173.1TFC
29.1TF
0AMH03 0079
99.1TF
2DAGS
0MWM
217.4AMH03 0078
214.1DAGS
2MGOGROUT HANGING IN PIPE
33.1TFC
0MWL
71TB
217MGOCONNECTION AT 9 O'CLOCK

Properties (5)

additional_info
SC345560
custom_field_two
4
customer
LACSD
datetime
2017-07-26T12:12:29-07:00
sewer_category