- Date
- 07/26/2017
- W/O
- 1590881
- Weather
- Dry
- Operator/Surveyor
- M.MARTINEZ
- Sewer ID
- Z00366
- PipeID
- P05100
- Time
- 12:12 PM
- Certificate
- U-115-06022794
- System Owner
- LACSD
- Date Cleaned
- —
- Pre-Cleaning
- Not Known
- Media Label
- K3993
- Sewer Name
- 03 LOS COYOTES DIAGONAL TRUNK
- City
- CERRITOS
- Loc. details
- Light Highway
- Location Code
- C
- Use of Sewer
- Sanitary Sewer
- District
- District 03
- Page No.
- 05
- Purpose
- Routine Assessment
- Project
- WO_646534_TV03011_JUL2017
- Material
- Vitrified Clay Pipe
- Shape
- Circular
- Height
- 12 in.
- Width
- 12 in.
- Upstream MH
- 03 0078
- Downstream MH
- 03 0077
- Dir. of Survey
- Downstream
- Length Surveyed
- 139.1 ft.
- Total Length
- 139.1 ft.
- Structural Index
- 0
- Structural Quick
- 0000
- Structural Rating
- 0
- O&M Index
- 2
- O&M Quick
- 2D00
- O&M Rating
- 54
- Overall Index
- 2
- Overall Quick
- —
- Overall Rating
- 54
Pipe schematic from manhole 03 0078 to 03 0077 Observation photos (1)

2.1 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start