Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jul 27, 2020, 07:12 PM
  • 03 0069_03 0068_15082017_155124.mp4

Date
07/27/2020
W/O
1590881
Weather
Dry
Operator/Surveyor
M.MARTINEZ
Sewer ID
Z00366
PipeID
P05090
Time
12:12 PM
Certificate
U-115-06022794
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K3993
Sewer Name
03 LOS COYOTES DIAGONAL TRUNK
City
CERRITOS
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 03
Page No.
05
Purpose
Routine Assessment
Project
WO_646534_TV03011_JUL2017
Material
Vitrified Clay Pipe
Shape
Circular
Height
15 in.
Width
15 in.
Upstream MH
03 0069
Downstream MH
03 0068
Dir. of Survey
Downstream
Length Surveyed
261.8 ft.
Total Length
261.8 ft.
Structural Index
1
Structural Quick
1100
Structural Rating
1
O&M Index
2
O&M Quick
412J
O&M Rating
114
Overall Index
2
Overall Quick
Overall Rating
115
Pipe schematic from manhole 03 0069 to 03 0068
MH: 03 0069MH: 03 0068downstream0 ft. AMH - Upstream Manhole, Survey Begins - 03 00690 ft. MWL - Water Level, 10 %of cross sectional area0 ft. MWM - Water Mark, 50 %of cross sectional area3.1 ft. DAGS - Deposits Attached Grease, 10 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start26 ft. TF - Tap Factory Made, at 12 o'clock, -, within 8 inches of joint: YES, 6"39.1 ft. DAE - Deposits Attached Encrustation, 10 %of cross sectional area, from 08 to 04 o'clock, , within 8 inches of joint: YES74.1 ft. DAE - Deposits Attached Encrustation, 10 %of cross sectional area, from 08 to 04 o'clock, , within 8 inches of joint: YES85.1 ft. DAE - Deposits Attached Encrustation, 5 %of cross sectional area, from 08 to 04 o'clock, , within 8 inches of joint: YES142 ft. TB - Tap Break-In, at 12 o'clock, -, within 8 inches of joint: YES, 6"179.1 ft. CC - Crack Circumferential, from 09 to 10 o'clock, within 8 inches of joint: YES195.1 ft. TB - Tap Break-In, at 12 o'clock, -, within 8 inches of joint: YES, 6"245 ft. DAE - Deposits Attached Encrustation, 5 %of cross sectional area, from 08 to 04 o'clock, , within 8 inches of joint: YES259 ft. DAGS - Deposits Attached Grease, 10 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish261.1 ft. MGO - General Observation - CONNECTION AT MH 9 O'CLOCK261.8 ft. AMH - Downstream Manhole, Survey Ends - 03 0068

Observation photos (6)

  • Deposits Attached Grease, 10 %of cross sectional area, from 04 to 08 o'clock,  , within 8 inches of joint: YES, Start

    3.1 ft. - Deposits Attached Grease, 10 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start

  • Deposits Attached Encrustation, 10 %of cross sectional area, from 08 to 04 o'clock,  , within 8 inches of joint: YES

    39.1 ft. - Deposits Attached Encrustation, 10 %of cross sectional area, from 08 to 04 o'clock, , within 8 inches of joint: YES

  • Deposits Attached Encrustation, 10 %of cross sectional area, from 08 to 04 o'clock,  , within 8 inches of joint: YES

    74.1 ft. - Deposits Attached Encrustation, 10 %of cross sectional area, from 08 to 04 o'clock, , within 8 inches of joint: YES

  • Deposits Attached Encrustation, 5 %of cross sectional area, from 08 to 04 o'clock,  , within 8 inches of joint: YES

    85.1 ft. - Deposits Attached Encrustation, 5 %of cross sectional area, from 08 to 04 o'clock, , within 8 inches of joint: YES

  • Crack Circumferential, from 09 to 10 o'clock, within 8 inches of joint: YES

    179.1 ft. - Crack Circumferential, from 09 to 10 o'clock, within 8 inches of joint: YES

  • Deposits Attached Encrustation, 5 %of cross sectional area, from 08 to 04 o'clock,  , within 8 inches of joint: YES

    245 ft. - Deposits Attached Encrustation, 5 %of cross sectional area, from 08 to 04 o'clock, , within 8 inches of joint: YES

Observations (15)

DistanceCodeObservation
0AMH03 0069
0MWL
85.1DAE
261.1MGOCONNECTION AT MH 9 O'CLOCK
245DAE
195.1TB
179.1CC
3.1DAGS
74.1DAE
261.8AMH03 0068
0MWM
26TF
39.1DAE
259DAGS
142TB

Properties (5)

additional_info
SC345560
custom_field_two
4
customer
LACSD
datetime
2020-07-27T12:12:25-07:00
sewer_category