Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jul 28, 2017, 08:59 AM
  • 03 0551_03 0055_11082017_102700.mp4

Date
07/28/2017
W/O
646534
Weather
Dry
Operator/Surveyor
M.MARTINEZ
Sewer ID
Z00366
PipeID
P05076
Time
1:59 AM
Certificate
U-115-06022794
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K3994
Sewer Name
03 LOS COYOTES DIAGONAL TRUNK
City
LAKEWOOD
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 03
Page No.
09
Purpose
Routine Assessment
Project
WO_646534_TV03011_JUL2017
Material
Vitrified Clay Pipe
Shape
Circular
Height
15 in.
Width
15 in.
Upstream MH
03 0551
Downstream MH
03 0055
Dir. of Survey
Downstream
Length Surveyed
288.2 ft.
Total Length
288.2 ft.
Structural Index
3
Structural Quick
4231
Structural Rating
13
O&M Index
2
O&M Quick
2100
O&M Rating
2
Overall Index
3
Overall Quick
Overall Rating
15
Pipe schematic from manhole 03 0551 to 03 0055
MH: 03 0551MH: 03 0055downstream0 ft. MWM - Water Mark, 40 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 03 05510 ft. MWL - Water Level, 10 %of cross sectional area2.2 ft. FM - Fracture Multiple, from 11 to 12 o'clock, within 8 inches of joint: YES, Start8.7 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start21.5 ft. TFC - Tap Factory Made Capped, at 12 o'clock, -, within 8 inches of joint: YES, 6"21.5 ft. FM - Fracture Multiple, from 11 to 12 o'clock, within 8 inches of joint: YES, Finish69.6 ft. FM - Fracture Multiple, from 12 to 02 o'clock, within 8 inches of joint: YES, Start98.4 ft. TFC - Tap Factory Made Capped, at 12 o'clock, -, within 8 inches of joint: YES, 6"109 ft. FM - Fracture Multiple, from 12 to 02 o'clock, within 8 inches of joint: YES, Finish156.8 ft. FL - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES, Start180.9 ft. FL - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES, Finish269.4 ft. CS - Crack Spiral, from 06 to 09 o'clock, within 8 inches of joint: YES285 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish288.2 ft. AMH - Downstream Manhole, Survey Ends - 03 0055

Observation photos (5)

  • Fracture Multiple, from 11 to 12 o'clock, within 8 inches of joint: YES, Start

    2.2 ft. - Fracture Multiple, from 11 to 12 o'clock, within 8 inches of joint: YES, Start

  • Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock,  , within 8 inches of joint: YES, Start

    8.7 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start

  • Fracture Multiple, from 12 to 02 o'clock, within 8 inches of joint: YES, Start

    69.6 ft. - Fracture Multiple, from 12 to 02 o'clock, within 8 inches of joint: YES, Start

  • Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES, Start

    156.8 ft. - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES, Start

  • Crack Spiral, from 06 to 09 o'clock, within 8 inches of joint: YES

    269.4 ft. - Crack Spiral, from 06 to 09 o'clock, within 8 inches of joint: YES

Observations (15)

DistanceCodeObservation
288.2AMH03 0055
21.5TFC
0MWM
180.9FL
0AMH03 0551
2.2FM
109FM
269.4CS
156.8FL
285DAGS
69.6FM
8.7DAGS
98.4TFC
0MWL
21.5FM

Properties (4)

custom_field_two
2
customer
LACSD
datetime
2017-07-28T01:59:43-07:00
sewer_category
Gravity